reference. The products are meant only to be used as a sauna heater and for heating the sauna.
1. THE ELECTRIC SAUNA HEATER PACKAGE INCLUDES:
1. Jacket for sauna heater
2. Stone holder and heating elements
3. Attachment plate + attachment nuts
4. Installation and operating instructions
The sauna controller is not included in the heaters price. The external controller that is connected with
the heater must be designed for sauna control purpose.
The control unit needs to fullfill referring local and European standards for electrical devices and sauna
heating appliances. The control unit must be equipped with a separate temperature sensor and safety
device (over heating protection) in accordance with standard EN 60335-2-53.

2. BEFORE INSTALLATION:

Check the following:
- The output of the sauna heater (in kW) is correct with respect to the size of the sauna (m
- The recommended volume of the sauna for each heater type is presented in the Table 1.
- If there is uninsulated brick, tile or glass wall surface in the sauna, to the inner volume of the sauna,
add 1.5 m
for every 1 m
3
the Table 1.
The volume of the sauna must be within the minimum and maximum values given by Table 1.
Table 1. Installation data for the Aura heater
Heater
Capacity
model
Volume
min
kW
m
3
Aura
4,5
4
Aura
6
6
Aura
9
9
- The minimum height of the steam room and the minimum safe distances are defined in the Table 1.
- Ensure that the surface, to which the attachment plate screws are fixed, is sufficiently firm.
A thin panel alone is not sufficient. Additional studding as a reinforcement behind the panel or rein-
forcement irons on top of the panel fastened to the wall studding can make the required reinforcement.
- The Aura sauna heaters of 4.5 kW or 6.0 kW can also be installed in a wall recess, provided that
the safe distances given by Figure 1 are observed.
- The Aura heater of 9.0 kW must not be installed in a wall recess.
INSTALLATION OF MORE THAN ONE ELECTRIC HEATER IN THE SAUNA IS NOT ALLOWED.
2
www.auroom.ee
of such wall surface, when selecting the heater with the correct output in
2
Steam room
Minimum safe distances to the heater
Height
At the
In the
side
front
max
min
A **)
B **)
m
3
cm
cm
7
190
5
9
190
5
15
190
5
**) See Figure 1
In the
To the
To the
front
ceiling
floor
C **)
D **)
E **)
cm
cm
cm
cm
8
2
115
12
8
2
115
12
10
2
115
12
*) Use a rubber-sheathed cable of type H07RN-F or equivalent
as the connecting cable
).
3
Stone
Connection *)
volume
400 V 3N
Fuses
kg
mm
2
A
25
5x1,5
3x10
25
5x1,5
3x10
25
5x2,5
3x16