GB
Adjustment during installation
The room sensor is primarily intended to correct decreases
in room temperature due to causes other than changes
in the outdoor temperature, for example, centralised load
control.
The required temperature can be set using the knob on
the room sensor unit. The number 5 corresponds approx-
imately to 2 °C. Reading the set temperature can be
done on the display screen of all NIBE-heating systems,
except EVC 3.
The room sensor corrects the curve slope so that the flow
temperature changes. If the room temperature changes
the room sensor senses this and lets the processor change
the flow temperature.
Any radiator valves ought to be fully open in areas where
the room sensor is installed.
Note!
Work behind screwed covers may only
be carried out under the supervision of a
qualified installation engineer.
6
External control of the room tempe-
rature*, extra option
The room temperature can be altered between two pre-
set values. If the room sensor connection is supplemented
with an external potential free contact function, for ex-
ample telephone switch or clock, the preset values can be
used. When the contact function is made the room sensor
is connected and influences the flow temperature.
Example: The basic setting gives a specific flow tempera-
ture. The room sensor is set to a lower temperature. When
the contact is made, the lower temperature applies until
the contact will be broken again.
Connection to be done on terminal block 4/X in all
before mentioned heat pumps and electric boilers.
* Does not apply to FIGHTER 20 and 220.
NIBE RG 10
6
1
2
F
G
H
Room sensor RG 0
Rumsgivare, RG 10
6
1
2
F
G
H
External modem not
Externt telefonmodem
supplied by NIBE
erhålls ej av Nibe
Potential free
potentialfri
kontakt
contact
4
5
6
Inkoppling på plint 14 i värmepump eller elpanna.