Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Annexes (English); Spare Parts; Troubleshooting - Thermopatch NL-33 Anleitung

Pneumatisch betriebene patchmaschine mit großen pressplatten
Vorschau ausblenden Andere Handbücher für NL-33:
Inhaltsverzeichnis

Werbung

9. Technical annexes (English)

9.1 Spare Parts

Reference
ELECTRICAL PARTS
CAR-CO2
SPA27-005
SPA3X-024
SPA3X-003
2
PNEUMATIC PARTS
VER-SM29
FIL-013
ELE-SM3
TEFLON and SILICONE RUBBER
SPA3X-100-7
SPA3X-019

9.2 Troubleshooting

Problem
The machine
The plug is not connected
does not
The switch has not been
switch on
switched to 'on'
Main fuse is not working
The heating
Faulty heating element
platenn does
Problem with the main
not heat up
board
Temperature set too low
The heat-
Problem with the probe
ing element
of electronic board
overheats
The timer
Disabled or faulty cylin-
does not
der sensor
count down
Problem with the elec-
tronic board
The press
The buttons are not
head does
working
not lower
Leaking cylinder
Too low pressure on air
supply
The press
Faulty solenoid control
head does
valve
not come up
Leaking cylinder
The press
The timer is not counting
head stays
down
down after
pressing
Description
CONTROL BOARD
MICA HEATING ELEMENT 400x500 2500W
TEMPERATURE PROBE
FUSE 5 x 20 mm T 16 A 250 V
CYLINDER Ø100 C50
AIR FILTER
SOLENOID CONTROL VALVE 5/2 G1/8 12V
FOAM 9.53 mm 400 x 500
TEFLON SHEET
Possible cause
Solution
Check the connection to the electric
mains and if the machine is plugged in
Press the main switch to 'on
The fuse is located in the fuse holder
next to the power cord connector.
Check the connections and the condi-
tion of the wiring
Remove the heating element
Check the on-screen messages and
refer to the section error messages,
page 9
Check de messages on the LCD
screen, page 9
Contact your supplier
Check the connections
Check the on-screen messages and
refer to the section error messages,
page 9
Check the connections
Check the seals and all connections,
contact your supplier
Check the valve couplings, contact
your supplier for replacement
Check that the air supplied is above 3
bar
Check the valve couplings, contact
your supplier for replacement
Check the seals and all connections,
contact your supplier
See above
Quantity
1
1
1
1
1
1
1
1
19