10. Fault-finding and rectification
1. The machine does not start.
Cause:
•
Main plug not inserted
•
Faulty connecting cable
•
On/off Switch on the control bar is faulty
•
Faulty capacitor
2. Motro does not run
Cause:
•
Damaged belt
•
No power to motor
•
Motor overload protection has switched the
motor off
3. Macine runs roughly.
Cause:
•
Soiled brush or pad
•
Pad is not centred
•
Pad/brush unevenly worn.
4. Insufficient suction.
Cause:
•
Suction ring unevenly adjusted
•
Suction lip faulty or worn
•
Dust bag full
•
Motor filter blocked
•
Suction hose leaky
11. Technical Data
Type:
Voltage
Frequency
Protection class
Protection grade
Drive motor
Vacuum motor
Vacuum
Brush – ø
Pad – ø
Rotation speed
Brush pressure
Torque
Cable length
Noise level
Weight
Filter area
Separation efficiency
Dust bag
CE testing
ES 545
V
230-240
Hz
50
I
IP
44
W
2000
W
1100
kPa
18,5
mm
500
mm
460
1/min
450
g/cm²
35
Nm
42
m
20
dB(A)
68
kg
50
cm²
3.375
%
99
I
9.75
Yes
EC Declaration of Conformity
Manufacturer:
Schwamborn Gerätebau GmbH
Robert-Bosch Str. 8
D-73117 Wangen bei Göppingen
Germany
We hereby declare that the design of the
equipment with serial number:
ES 545:
........................................................
has been manufactured in accordance with the
following Council directives:
In the sense of EC Machine Directive 2006/42
EC Low Voltage Directive 2006/95 EC
EMC Directive 2004/1 08 EC
DIN EN 60335-2-67:
DIN EN 60335-1:
DIN EN 13857 :
DIN EN 60204-1 : 2007-06/A1 2009-10
DIN EN 55014-1:
DIN EN 55014-2:
DIN EN 61000-3-2:
DIN EN 61000-3-3:
29/12/09
Eckart Schwamborn
General Manager
8
EC
2010-01
2007-02
2008-06
2007-06
2009-06
2006-10
2009-06