7.3 REPLACE THE DRIVER BLADE/ANVILS
–
Disconnect tool from air supply.
–
Remove six screws (Fig. 11/1) holding the rear
body to the front section.
–
Remove the rear body (11/2) with magazine.
–
Replace the driver blade (11/3).
–
Assemble parts in reverse order.
If changing the anvils always change both at the same
time:
–
Remove the driver blade (11/3).
–
Remove the screw (11/4).
–
Replace the anvils (11/5).
–
Assemble parts in reverse order.