The loading lever should be placed in calibration center to ensure better accuracy. Is often marking in the middle of the
handle.
5.
SENSORS
REF
Sensor
E.6000-C1000 10-1000 N.m
E.6000-C400
20-400 N.m
E.6000-C50
5-50 N.m
E.6000-C30
1-30 N.m
E-6000-C5
0,5-5 N.m
E-6000-C12
0,04-1 N.m
REF
Low
E.6000-C1000
E.6000-C400
E.6000-C50
E.6000-C30
NU-CD.12A_0817.indd 15
External
Square (")
Dimensions
(LxWxH)
(mm)
160x105x108
145x92x92
105x65x80
105x65x80
105x65x80
105x65x80
Range
High
10
1000
20
400
5
50
1
30
Mounting
FACOM
Distance
(Class 12.9)
(mm)
3/4 "
114
1/2 "
100
3/8 "
70
1/4 "
70
1/4 "
70
1/4 "
70
Accuracy
1%
0.50%
10-99
100-1000
20-39
40-400
N/A
5-50
1-2
3-30
F
CALIBRATION CENTER
Screws
ScrewHole
M14
Ø15
M12
Ø13
M8
Ø9
M8
Ø9
M8
Ø9
M8
Ø9
Torque
range for
screw
120 N.m
100 N.m
40 N.m
40 N.m
40 N.m
40 N.m
15