If you wish to remove the contents from the steriliser, use the tongs (8) provided in
order to avoid burns due to the contents being hot.
IMPORTANT: Allow the steriliser to cool down for at least 20 minutes before sterilising
again.
14. After three hours have passed following the termination of the sterilisation process,
an informational auditory signal will sound for the user's attention and the device
will automatically switch itself off.
IMPORTANT: Make sure that all the elements to be sterilised are positioned in such a
way that the water that condenses from the steam will not build up but rather drain away
and fall unobstructed to the bottom of the device.

6. MAINTENANCE

Follow the instructions below for any maintenance tasks:
• Main body:
∙ Always power the device down and unplug it before proceeding with any cleaning
tasks.
∙ Only use a damp cloth to clean it.
• Heating chamber:
∙ Depending on the quality of the water used, lime deposits may build up over time at
the base of the heating chamber.
∙ These lime deposits must be removed regularly by pouring a mixture of 200 ml of
cold water and 100 ml of white vinegar into the heating chamber. Pour directly into
the tank and allow to soak until the lime has dissolved.
∙ There are specific products on the market for removing lime from this type of device;
they can also be used to clean it. In any case, before using them, make sure that
they are not abrasive.
• Removable accessories:
∙ All the accessories are dishwasher safe.

7. LOCATING FAILURES

SYMPTOMS
Display light switched off
The device has reduced
effectiveness when
generating steam
The device works but it
does not generate steam
Other malfunctions
POSSIBLE CAUSES AND CORRECTIVE MEASURES
Check that the device is plugged in and push the
power button
Check if there are any lime deposits in the heating
chamber. Clean the chamber by following the
instructions in point 6 as many times as may be
necessary nor normal operation to be restored
Get in touch with the Miniland technical service