Terminal board connections
CMN common for all inputs and outputs.
7
8
ELS electric lock output (fed continuously) 12 Vdc - 15 W.
9-10 LC-CH2 Potential free contact for the activation of the courtesy light
(separate power supply Vmax=30 Vac/dc: Imax=1A) or the second radio
channel. Selection is carried out in the "options" menu.
11
CMN common for all inputs and outputs.
12
LP 24 Vdc 25 W output for warning lights intermittent activation (50%),
12,5 W continuous activation.
LS 24 Vdc 3 W output for an indicator light.
13
14
CMN common for all inputs and outputs.
15
24 Vdc controlled output, powering external loads
CMN common for all inputs and outputs.
16
24 Vdc output, powering external loads
17
18
TA (NO contact) opening button input.
19
TC (NO contact) closing button input.
20
TAL (NO contact) limited opening button input.
TD (NO contact) dynamic button input.
21
22
CMN common for all inputs and outputs.
23
TB (N.C./8.2 kΩ contact) stop button input (The opening of this contact
interrupts the cycle until a new movement command is given).
CP (N.C./8.2 kΩ contact) safety edge input. Opening this contact will
24
provoke a travel direction inversion during the closing stage and during
the opening stage.
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
25
FS (N.C./8.2 kΩ contact) The opening of this contact will block all move-
ment, until the obstruction has been removed and the pause time has
elapsed, due to the safety device cutting in, the door will then continue
moving in the closing direction (only with automatic reclosing enabled).
26
FI (N.C./8.2 kΩ contact) safety and control devices in input (photocells
invert the travel direction when an obstruction is detected). Opening this
contact will provoke a travel direction inversion during closure due to the
cutting in of the safety device.
27
Outer conductor for radio receiver antenna.
28
Inner conductor for radio receiver antenna (if an external antenna is fitted
use a coaxial type cable RG58 with an impedance of 50Ω).
29
CMN common for the emergency buttons.
31
EMRG1 (NO) emergency manoeuvre input 1.
EMRG2 (NO) emergency manoeuvre input 2.
30
Note
The total of the 2 external device outputs must not exceed 10 W.
(1)
TRANSFORMER
L2
J5
F3 10 A
F4 10 A
L1
Collegamento motori/encoder a 4 fili
Connecting motor/4-wire encoder
Branchement moteur/encodeur à 4 fils
Anschluss der Motor/Encoder mit 4 Drähten
Conexionado motores/encoder de 4 conductores
COLORE
COLOUR CODE
CABLAGGI
CODE
Bl
Blu
Blue
Gr
Verde
Green
Gy
Grigio
Grey
Yw
Giallo
Yellow
KABELFARBEN
COLORACIÓN
CABLEADOS
Bl
Blau
Azul
Gr
Grün
Verde
Gy
Grau
Gris
Yw
Gelb
Amarillo
ENCODER 1
M1
Bl
Gr
Gy
Yw
1
2
3
4
5
6
1
B1
Signal buzzer "via radio" mode
(4)
F1
4A
blade fuse
(24V circuit protection)
(4)
F2
4A
blade fuse
(24V circuit protection during battery operation)
(4)
F3
10A blade fuse
(motor power protection)
(4)
F4
10A blade fuse
(motor protection during battery operation)
J1
Display orientation selection
J2
Serial connection CSER (not connected)
J3
Battery connection
J4
Battery charger slot
.
(1)
(1)
.
J3
BATTERY
CHARGER
COLORATION
DES CÂBLAGES
Bleu
Vert
Gris
Jaune
LC/CH2
ENCODER 2
M2
Bl
Gr
Gy
Yw
7
8
9
2
3
4
5
6
ALL UNUSED NC CONTACTS MUST BE JUMPED and consequently the
security device test (FI , FS ) must also be deactivated. If you want to activate
the FI, FS test both the transmission and receiver parts of the security devices
must be connected to the binding post marked "CTRL 24 Vdc".
If the test is active there will be a 1 second
delay between the command transmission
and movement of the gate/s.
• Switch on the power and make sure that the
indicator LEDs are in the following condition.
- L1 Power on
- L2 Wrong battery connection OFF
Indications on the display
- S1 Indicator for the blocking button
- S2 Indicator for the inverting photoelectric cells
- S3 Indicator for the stop photoelectric cells
- S4 Indicator for the safety edge
- S5 Indicator for the opening button
- S6 Indicator for the closing button
- S7 Indicator for the sequential command
- S8 Indicator for the limited opening button
Note
: If this LED is "ON" disconnect the battery power cables
(2)
immediately.
Note
: If the security device has not been activated the indications on
(3)
the display are at rest. Make sure that when the security device
is activated the status is inverted (black characters on a white
background).
If the green power on LED "L1" doesn't light up check the condition of the
fuses and the power cable connection at the transformer primary.
If one or more of the safety indications "S1, S2, S3, S4" are active (black
characters on a white background) check the contacts of the relative security
devices and check that the unused safety device contacts have been bridged.
The indications "S5, S6, S7, S8" change status on the display when the
relative command is activated, eg. pressing the button "TA" will change the
status from 'at rest' to 'active' (white characters on a black background).
CS1422A DC0556
J4
B1
R1
10
11
12
13
14
15
16
17
18
J5
Transformer secondary connection
J6
Emergency enable jumper
LCD1 LCD Display
M1
Transmitter code memory module
P1
Menu navigation button (
P2
Programming and confirm button (PROG./OK)
P3
Menu navigation button (
R1
Radio frequency module, 433 MHz (868 MHz on request)
(4)
Note
: These are automotive type blade fuses (max. voltage 58 V)
13
TB FI
S1
FS CP
S3
00.000.007
CC2X24
ON
(2)
at rest
TB
FI
FS
CP
TA
TC
TD
TAL
J1
M1
PROGRAM
TB FI
FS CP
00.000.007
CC2X24
P1
P2
PROG/OK
J6
19
20
21
22
23
24
25
26
27
)
)
S2
S5
S7
TA TD
TC TAL
S8
S4
S6
V1.00
activated
(3)
TB
(3)
FI
(3)
FS
(3)
CP
TA
TC
TD
TAL
J2
TA TD
TC TAL
V1.00
P3
28
29 30 31

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Cc242etopCc242extop

Inhaltsverzeichnis