Initial operation

Use the pressure adjustment screw of the
system pressure gauge (P) to adjust the
system pressure to 0.5 bar ( TUNZE 7074).
Screwing the screw in will increase the
pressure, unscrew the screw will decrease the
pressure at the gas exit (O).
If, by mistake, the system pressure was set to
over 4 bar, the safety valve (R) attached to the
pressure gauge (M) will relieve the pressure
automatically.
Normally, the cylinder pressure of a full cylinder
is abt. 50 bar, depending on the temperature.
Start CO2 at the pH-Controller, and check the
inflowing CO2 in the aquarium. Screw in the
fine adjustment valve (L) to set the required
gas discharge pressure.

Mise en service

A l'aide la vis (K) du réducteur de pression,
ajustez la pression d'utilisation de l'installation
à 0,5 bar (par exemple, lors de l'utilisation du
contrôleur TUNZE 7074). En tournant la vis
dans le sens horaire, la pression d'utilisation
en (O) est augmentée. En tournant dans le
sens anti-horaire, la pression est diminuée.
Si la pression d'utilisation dépasse 4 bars sur
le manomètre (M), la soupape interne ( R) se
déclenche automatiquement.
La pression interne normale d'une bouteille
CO2 est de 50 bars en fonction de la
température ambiante.
Nous conseillons le pilotage de l'installation
par un contrôleur CO2.
Le débit de CO2 (nombre de bulles) s'ajuste
par le robinet de réglage fin en partie
inférieure (L).