AXIS Q6055-C PTZ Dome Network Camera
DC power to camera
Network (Ethernet 10/100Base-T)
Input/Output (I/O)
Multicable overview
1
Power wire (red)
2
Digital I/O wire (blue)
3
Ethernet wire (green/white)
4
Ethernet wire (green)
5
Ethernet wire (orange/white)
6
Ethernet wire (orange)
7
Digital I/O wire (yellow)
8
Ground wire (black)
9
Power wire (red)
10 Ethernet wire foil shield (2x)
11 Braided shield coil
Function
Pin – wire
Configurable
2 – blue
(Input or
7 – yellow
Output)
Notes
Digital input – Connect to pin
8 to activate, or leave floating
(unconnected) to deactivate.
Digital output – Connected to
pin 1 when activated, floating
(unconnected) when deactivated. If
used with an inductive load, e.g. a
relay, a diode must be connected in
parallel with the load, for protection
against voltage transients.
26
Specifications
0 to max 30 V DC
0 to max 30 V DC,
open drain,
100 mA