S = Standard, L = Loco address, W = Switch address, LW = Loco- und Switch address usable
CV
Beschreibung
1
XpressNet slave address
2
Bus
3
debounce
4
Radio band
5
Radio channel
6
programming lock
7
software version
7
2 Reset ranges selectable
8
Manufacturer ID
7+8
Reg8 = CV address
Reg7 = CV value
9
Radio ID
10
L1 / K1 address high
11
L1 / K1 address low
12
L1 / K1 time delay
13
L1 / K1 inversion
14
L1 / K1 configuration
15
L2 / K2 address high
16
L2 / K2 address deep
17
L2 / K2 time delay
18
L2 / K2 inversion
19
L2 / K2 configuration
20
L3 / K3 address high
21
L3 / K3 address deep
22
L3 / K3 time delay
23
L3 / K3 inversion
24
L3 / K3 configuration
14
CV-Table
S
L/W
Bereich
1
0 – 32
0
0
20
0 – 255
0
0 -2
0
0 – 255
160
0/160
–
–
Decoder-Resetfunktionen
11
16
160
–
Registerprogramiermodus
165
0 – 255
0
W
1 - 2048
1
W
0
W
0 – 255
0
W
0/1
6
W
0 – 6
0
W
1 - 2048
1
W
0
W
0 – 255
0
W
0/1
6
W
0 – 6
0
W
1 - 2048
1
W
0
W
0 – 255
0
W
0/1
6
W
0 – 6
Bemerkung
0 = disabled, 1-32 slave address
0 = XpressNet
100ms / value debounce time inputs
0 = 434 Mhz
1 = 868 Mhz
2 = 915 Mhz (US)
radio channel
Module is completely reset
Programming lock (CV 6)
read only
CV 7/8 retain their value
First describe the CV 8 with destination
address, then write or read CV 7 with value
(eg: CV 19 should have 3)
➔ CV 8 = 19, CV 7 = 3 send
Radio ID for feedback
Switch address which is confirmed or
switched (depending on configuration)
Message delay / delay switch
0 = normal, 1 inverted
see Annex 1
Switch address which is confirmed or
switched (depending on configuration)
Message delay / delay switch
0 = normal, 1 inverted
see Annex 1
Switch address which is confirmed or
switched (depending on configuration)
Message delay / delay switch
0 = normal, 1 inverted
see Annex 1
RBM