Herunterladen Diese Seite drucken

Axor Citterio Select Gebrauchsanleitung, Montageanleitung Seite 2

Werbung

EN
2
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
⁄ During initial start-up and after servicing, air in the fittings can cause noise. After
switching the jet on and off about 15 times, the noise will stop.
T E C H N I C A L D A T A
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
F A U L T
⁄ Mixer stiff
⁄ Mixer dripping
⁄ Low flow with Select valve after valve replacement
⁄ Water escaping in area of swivel spout
⁄ Water escaping at the threaded base
⁄ Hot water temperature too low
⁄ Select button stiff
A S S E M B L Y (see page 4)
S Y M B O L D E S C R I P T I O N
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
65°C
max. 70°C / 4 min
C A U S E
⁄ Cartridge defective, calcified
⁄ Cartridge defective
⁄ Improper Select valve installed
⁄ O-ring defective
⁄ connection hoses not completely screwed into basic body
⁄ O-ring at the connection hose defective.
⁄ Hot water limiter incorrectly set
⁄ Select button soiled
Do not use silicone containing acetic acid!
A D J U S T M E N T (see page 7)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
D I M E N S I O N S (see page 7)
F L O W D I A G R A M (see page 7)
O P E R A T I O N (see page 8)
⁄ Hansgrohe recommends not to use as drinking water the first half liter of
water drawn in the morning or after a prolonged period of non-use.
⁄ Minor leaking may occur briefly at the spout when opening the fitting via
the lever.
⁄ Use the lever to open the tap and set the desired temperature. The water
flow can be paused by pressing the Select button on the face side of the
spout. When the tap is not used for a longer period of time, f.e. when
retiring at night or leaving the house, it must be closed completely by
means of the lever.
M A I N T E N A N C E (see page 8)
The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
S P A R E P A R T S (see page 9)
C L E A N I N G
see enclosed brochure
R E M E D Y
⁄ Exchange cartridge
⁄ Exchange cartridge
⁄ Replace Select valve #98462000
⁄ Exchange O-ring
⁄ Tighten connection hoses by hand
⁄ Exchange O-ring
⁄ Set hot water limiter
⁄ Clean Select button and grease 19x1,5 O-ring (see page
9)

Werbung

loading