CAUTION: The power supply 0 V should be terminated at the machine ground (star point). If a negative supply is
used, then the negative output must be fused.
The dc supply to this equipment must be derived from a source which is approved to IEC/BS/EN 60950-1.
1-6
Wiring diagram (with output groupings shown)
Turquoise
Turquoise/black
Blue
Blue/black
Violet
Violet/black
Green
Green/black
White
Brown
Pink
12 V to 30 V
Red
0 V
Black
Green/yellow
Screen
Probe status 1 (SSR)
Probe status 2 (SSR
Low battery (SSR)
Error (SSR)
Machine start input (Probe 1)
Machine start common
Machine start input (Probe 2)
Power supply (12 V to 30 V)
Machine ground (star point)