Herunterladen Inhalt Inhalt Diese Seite drucken

Parameterization Via Trwinprog; Velocity; Unit; Overspeed - TR-Electronic I__-582 Serie Benutzerhandbuch

Encoder
Vorschau ausblenden Andere Handbücher für I__-582 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Parameterization via TRWinProg

5 Parameterization via TRWinProg
In order to be able to change the parameterization, the TRWinProg programming
interface must be connected to the measuring system connector. If this is not the
case, the following parameters are firmly set to the customer specification.

5.1 Velocity

5.1.1 Velocity
In the online state in the field Velocity the current measuring system speed is
displayed. The value is output without sign and in the unit which is adjusted under the
parameter Unit.

5.1.2 Unit

Selection
U/s
U/min
U/h

5.1.3 Overspeed

Input of the switching threshold [min
Switching output = active, if the speed > switching threshold.
The switching threshold must be within the electrical maximum speed.
The measuring system checks the programmed overspeed and aborts the input, if the
electrical maximum speed is exceeded. See also chapter "Max. permissible electrical
speed" on page 26.

5.2 Incremental

5.2.1 Number of impulses

Specification of the output pulses per revolution.
Lower limit
Upper limit IE_
Upper limit IO_
Upper limit IP_
Programmability
 TR-Electronic GmbH 2015, All Rights Reserved
Page 32 of 35
Description
Output of the Velocity in revolutions per second
Output of the Velocity in revolutions per minute
Output of the Velocity in revolutions per hour
-1
] for the switching output "Speed", see page 30.
2
10000
65536
10000
1-step
TR - ECE - BA - DGB - 0119 - 04
Default
X
Printed in the Federal Republic of Germany
07/11/2018