Herunterladen Inhalt Inhalt Diese Seite drucken

F/B Function (Counting Direction - Input); Switching Output Speed - TR-Electronic I__-582 Serie Benutzerhandbuch

Encoder
Vorschau ausblenden Andere Handbücher für I__-582 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation / Commissioning
4.4 F/B function (Counting direction – input)
With connection of the external input with supply voltage, the actual adjusted counting
direction is inverted.

4.5 Switching output speed

The type of the "Switching output speed" depends on the type of the scanning unit of
the measuring system. Measuring systems with optical scanning units are equipped
with a short-circuit proof open-collector switching output and measuring systems with
magnetic code disc scanning units are equipped with a Push/Pull switching output.
The switching threshold of the switching output can be adjusted via the parameter
Overspeed, see page 32.
Schematic output circuit diagram „Open Collector" (optical scanning unit):
The external pre-resistor R
current of 35 mA is not exceeded.
Schematic output circuit diagram „Push/Pull" (scanning unit with magnetic
code disc IP_58_):
 TR-Electronic GmbH 2015, All Rights Reserved
Page 30 of 35
must be selected in such a way that the maximum
ext
TR - ECE - BA - DGB - 0119 - 04
Printed in the Federal Republic of Germany
07/11/2018