8 Warnings
8.1 Flashing display
The display will flash if the temperature in the aquarium deviates from
the set value by more than + 3 or – 3 °C.
Check immediately:
• Are the heating systems working correctly?
• Is the temperature sensor secured correctly?
8.2 Acoustic alarm
The acoustic alarm can be activated in addition to the visual alarm.
This is expedient when the Duomat is installed in the base cabinet of
the aquarium, for example:
• To activate the acoustic alarm: Press key - LED goes ON
• To deactivate the acoustic alarm: Press key again - LED goes OFF

9 Comfort functions

9.1 Dimming the display
The display and all LEDs can be dimmed to adapt them perfectly to
the ambient light conditions:
• Press "Dimmer" key and set the desired brightness with "+" and
"–".
• If the keys remain unused for 3 sec., this value will be adopted.
Possible dimming levels: 1-8
9.2 Keypad lock (child-proof safety lock)
The keypad lock prevents unintentional alteration of the programmed
settings:
• To activate the keypad lock: Press "Dimmer" and "°C" keys simul-
taneously, "Keypad lock" LED lights up
• To deactivate the keypad lock: Press key combination again,
LED goes off
Note: If any key is pressed while the keypad lock is active, "SAF" (for
SAFE) will appear on the display. The only available functions are
display of the set temperature and the time via the appropriate keys.
28
10 What if ... Troubleshooting
10.3 Possible causes of faults
Fault
Set temperature is
not reached
Desired temperature
reduction is not
achieved
Heating system not
working, although
indicator lamp ON
DENNERLE
Duomat Evolution DeLuxe
10.1 Replacing the fuses
If one of the connected heating system fails to work although the
corresponding LED indicates that it is on, either the heating system or
the fuse is defective.
• Checking the fuse: Connect standard table lamp to the socket on
the power unit. Set required temperature sufficiently high for the
heating system to be activated. If the lamp does not light up, the
fuse is defective.
• Replacing the fuse: Disconnect the Duomat from the mains.
Unscrew fuse holder and remove defective fuse. Fit new fuse
of the same type (from electrical retailer) and screw fuse holder
back into place.
10.2 What will happen in case of a power failure?
In case of a power failure, all programmed settings and functions will
be retained in the internal permanent memory. As soon as the power
supply to the Duomat is resumed, it will automatically perform the
necessary control actions to restore the temperature in the aquarium
to the set value.
Cause
Remedy
Adjustable heater set too low
Set required temperature higher
on adjustable heater
Capacity of adjustable heater too
Use adjustable heater with higher
low
heating capacity
Temperature sensor positioned
Secure temperature sensor at spot
incorrectly
where the water movement is good
Fix sensor back correctly in
Sensor has slipped out of aquarium
position
Room temperature too high
Lower room temperature
Aquarium too well insulated
Improve heat exchange
Heating system defective
Check heating system, replace if
necessary
Replace fuse, see 10.1
Fuse defective