INSTALLATION/PAIRING OF DEVICES
1. Choose suitable positions for installation of smoke detectors (fig. B)
and fix base plate (fig. 1).
2. Start the smoke detector by moving the power switch to the 'ON' position
(fig. 2).
3. Connect the smoke detectors wirelessly as follows:
3:1 Press the grey button for one second until you hear one beep to
initiate pairing mode. The indicator light will flash red (fig. 3).
3:2 Repeat the same procedure on the next device. After about two
seconds you will hear two beeps from each of the devices, and at the
same time the indicator lamp will flash red twice to indicate that they
are paired.
3:3 To pair more than two devices, repeat steps 3:1 and 3:2, using
any already paired device and a new device. If pairing does not occur,
pairing mode is cancelled after 15 seconds (fig. 3).
4. Attach the smoke detector to the base plate by turning it clockwise (fig. 4).
5. Ensure that all smoke detectors are paired by testing the alarm.
TESTING THE SMOKE DETECTOR
Test the smoke detector by pressing the outer part against the base plate
for three seconds until you hear a beep. To test all paired devices, continue
to press the outer part for a further three seconds while it beeps until all
paired devices emit an alarm (fig. 5).
When one device is tested, it emits an alarm in the form of a continuous
beep for ten seconds. When a series of paired devices are tested, other
devices emit an alarm in the form of a pulsating sound for about 18 sec-
onds. The device where the test began can be silenced by pressing the
outer part again. The other devices will continue for 18 seconds until the
end of the test period.
N.B. Test the smoke detector only by pressing on the front. Testing
with a naked flame or smoke can cause a fire.
If a paired device does not emit an alarm signal when tested, it may be out
of range or the battery may be dead. First check that the power switch of
the device is set to ON, and check that you hear a beep when the device is
pressed against the base plate for three seconds. Then move the smoke
detector closer to another paired device and test it again, to check whether
the distance is too great and another paired device is therefore required.
In normal operation, the smoke detector emits no signals and does not
flash.