8
Troubleshooting and fault elimination
Pos : 11.2 /1 Gr undleg ende Si cherheits hinweis e/Sic herheitsi nformati onen Wechs elstr om-Geräte/Ü berschrift: Sicherheits hi nweis e @ 0\mod_1269594836071_131.doc x @ 3742 @ 2 @ 1
8.1
Safety instructions
Pos : 11.3 /1 Gr undleg ende Si cherheits hinweis e/Sig nal wort-Fel d " Warnung" @ 0\mod_1261404807286_131.doc x @ 893 @ @ 1
Pos : 11.4 /1 Gr undleg ende Si cherheits hinweis e/Hinweis N etzstec ker ziehen @ 0\mod_1261407392098_131.doc x @ 939 @ @ 1
Before starting work remove the plug from the wall socket!
Pos : 11.5 /8 Stör ungss uc he und Stör ungs besei tigung/Sollten sc hädlic he Substanz en entweic hen, Maschi ne auss chalten, R aum l üften bz w. verl ass en. @ 2 \mod_1348551330162_131.doc x @ 30232 @ @ 1
If harmful substances escape due to a defect (eg filter defect), the machinery must be switched off
immediately and the room has to be aired or leave!
Pos : 11.6 /1 Gr undleg ende Si cherheits hinweis e/Sic herheitsi nformati onen Wechs elstr om-Geräte/vor Begi nn j eder Arbeit.... frei zuschalten @ 0\mod_1269594559993_131.doc x @ 3730 @ @ 1
•
Before starting any work on the industrial vacuum cleaner, but particularly before opening covers of
live or moving parts, the industrial vacuum cleaner or system must be correctly disconnected from
the mains and the drive unit must have stopped
Pos : 11.7 /1 Gr undleg ende Si cherheits hinweis e/Sic herheitsi nformati onen Wechs elstr om-Geräte/Di e nachs tehend genannten Maßnahmen dürfen erst dann z urüc kg enommen wer den @ 0\mod_1269594747884_131.doc x @ 3736 @ @ 1
•
The measures specified below may only be withdrawn when the industrial vacuum cleaner is
completely reassembled and the maintenance is concluded.
Pos : 11.8 /1 Gr undleg ende Si cherheits hinweis e/Sic herheitsi nformati onen Wechs elstr om-Geräte/Di e üblic hen Sic her hei tsregel n l auten hier bei z.B. nach VD E 0105 @ 0\mod_1269594914059_131.doc x @ 3748 @ @ 1
•
The usual safety regulations are, for example, in accordance with VDE 0105:
– Disconnect from mains
– Provide a safeguard to prevent unintentional restarting
– Check that the equipment is not live
– Cover or shield adjacent live parts.
Pos : 11.9 /8 Stör ungss uc he und Stör ungs besei tigung/Erste M aßnahmen z ur Stör ungsbesei tigung @ 0\mod_1263802336933_131.doc x @ 1492 @ 2 @ 1
8.2
Initial fault elimination measures
Pos : 11.10 /8 Störungss uche und Störungs bes eitigung/T ext vorT abelle der aufgeführ ten Störungen @ 0\mod_1263802646340_131.doc x @ 1504 @ @ 1
könne
All the errors mentioned in the table below may be eliminated by yourself. In case of major problems
or other failures please contact the customer service of Ringler immediately.
Tel. ++49-(0)7171-94888-0
Perform maintenance tasks in accordance with the description in the Maintenance/Servicing chapter
Pos : 11.11 /8 Störungss uche und Störungs bes eitigung/RI/Tabelle Störungen Spänes aug er Wec hs elstr om (RI 020) @ 4\mod_1362473323608_131.doc x @ 41456 @ @ 1
Fault
Reduced
suction capacity
Suction motor
not running
correctly
Fuses trip
Pos : 12.1 /9 Wartung/Instands etz ung/Wartung/Ins tandsetz ung, Kapitel übersc hrift @ 0\mod_1263808011795_131.doc x @ 1516 @ 1 @ 1
20/46
Possible cause
Suction tube or nozzle blocked
Suction tube leaking
Suction tube incorrectly positioned in
the suction nozzle
Collecting tank full
Bag-type filter soiled
Seal between drive unit and collecting
tank defective
A suction turbine is defective
Carbon brushes worn
Socket defective
Switch defective
Motor defective
Troubleshooting and fault elimination
WARNING
Elimination
Eliminate obstruction
Replace tube
Insert tube correctly
Empty collecting tank
Clean or replace filter
Clean or replace seal
Replacement of suction
turbine by qualified
electrician
Inspection by qualified
electrician
Inspection by qualified
electrician