PROBLEM : 'Inverter temperature too high. Cooling down' error
keeps on appearing
Possible cause :
Airflow around the inverter is
obstructed.
Too high ambient temperature.
Note: Don't turn-off the inverter when it's operating in an 'Inverter
temperature too high. Cooling down' error. The inverter needs this
error time to cool down.
PROBLEM : Inverter jumps between continuous mode and
economy mode all the time
Possible cause :
Connected load is not
compensated or the ratio between
inrush current and continuous
current is too large.
If none of the above remedies helps to solve the problem you encounter,
contact your local Victron Energy distributor for further help and/or
possible repair of your inverter. Do not open the inverter yourself, there
are dangerous high voltages present inside. Opening the inverter will
directly void your 12 months warranty period.
16
Remedy :
Make sure there is at least 10
centimetres of clearance around
the inverter. Remove any items
placed on or over the inverter.
Keep the inverter away from direct
sunlight or heat producing
equipment.
Move the inverter to a cooler place
or provide additional cooling by an
external fan.
Remedy :
Connect an additional load to the
output.