8 Troubleshooting
Fault
‡ Motor does not start
Motor does not run in
*)
automatic mode
The acoustic warning
sounds. (Reduced suction
power)
No suction power during
wet cleaning
Voltage fluctuations
*)
Optional accessories / Option depending on model
Original Instruction
Cause
> Fuse of the mains socket has
blown.
> Overload protection switch
has tripped.
> Motor is faulty.
> Power tool/pneumatic tool is
defective or not connected
properly.
> The power rating of the
electrical tool is too low.
> Suction power selected with
suction power control
low.
> Hose diameter does not
correspond with switch
position
> Clogged suction hose/nozzle.
> Tank, disposal bag or filter
bag is full.
> Filter element is clogged.
> Seal between tank and upper
section of vacuum cleaner is
faulty or missing.
> Cleaning mechanism is
defective.
> Tank is full.
> Impedance of power supply is
too high.
Remedy
• Connect mains fuse.
• Switch off the vacuum cleaner
and allow it to cool for approx.
5 minutes. If the cleaner
cannot be started again,
contact the ASUP service
department.
• Have motor changed by ASUP
Service.
• Check that the power tool
works or that the plug is
inserted correctly.
• Note that minimum power
rating is P>40W
• Set suction power in
*)
is too
accordance with section
„Setting suction power".
• Set correct switch position for
hose diameter
• Clean suction hose/nozzle
• See "Emptying tank" or
"Replacing disposal bag, filter
bag" sections.
• See section „Cleaning filter
element" and „Replacing filter
element".
• Replace seal.
• Contact ASUP Service.
• Switch off the cleaner. Empty
the tank.
Connect the cleaner to another
socket closer to the fuse box.
Voltage
7% should not occur if the
impedance at the transfer point
is 0.15 .
ASUP Enviro Dustkiller
fluctuations
over
37