suitable personal protection. Operate only after the full filtration sys-
tem has been fitted and checked.
The air flow in Safety Vacuum systems has to be strictly controlled
to achieve a minimum flow rate of V
The vacuum cleaner ASUP Enviro Dustkiller H 230V/50Hz EU are
suitable to pick up
dry, nonflammable dust, non flammable liquids, hazadous dusts
with OEL values, carcinogenic dusts, dusts containing germs
The vacuum cleaner ASUP Enviro Dustkiller H 230V/50Hz EU are
suitable to pick up
dry, nonflammable dust, non flammable liquids, sawdust and
hazadous dusts with OEL values > 0.1 mg/m³
The vacuum cleaner ASUP Enviro Dustkiller H 230V/50Hz EU are
also approved for asbestos abatement according to TRGS 519.
When dust removers are used, the rate at which air is exchanged
in the room must be adequate if the exhaust air from the vacuum
cleaner is blown into the room (please observe regulations valid in
your country).
The vacuum cleaner are suitable for commercial use, such as e.g. in
Hotels, Schools, Hospitals, Factories, Shops, Offices, Hire shops
Any other use is considered as improper use. The manufacturer ac-
cepts no liability for any damage resulting for such use. The risk for
such use is borne solely by the user.
Proper use also includes proper operation, servicing and repairs as
specified by the manufacturer.
1. Before transporting the dirt tank, close all the locks.
2. Do not tilt the cleaner if there is liquid in the dirt tank.
3. Do not use a crane hook to lift the cleaner.
1. Store the appliance in a dry place, protected from frost.
1. It is recommended that the vacuum cleaner should be connected
via a residual current circuit breaker.
2. Arrange the electrical parts (sockets, plugs and couplings) and
lay down the extension lead so that the protection class is main-
tained.
3. Connectors and couplings of power supply cords and extension
leads must be watertight.
1. As an extension lead, only use the version specified by the man-
ufacturer or one of a higher quality. See operating instructions.
2. When using an extension lead, check the minimum cross-sec-
tions of the cable:
Cable length
up to 20 m
20 to 50 m
= 20 m/s in the suction hose.
min
Cross section
< 16 A
< 25 A
2
1.5 mm
2.5 mm
2
2.5 mm
4.0 mm
ASUP Enviro Dustkiller
2
2
23