Herunterladen Inhalt Inhalt Diese Seite drucken

Internal Jumpers - Studer D19 MultiFeed Bedienungsanleitung

Sync/aes3 signal distributor
Inhaltsverzeichnis

Werbung

D19 MultiFeed
3.2

Internal Jumpers

Caution:
Factory Setting:
[1]
[2]
[3]
[4]
[5]
E 3/2 DIP switch and jumpers
All internal adjustments as well as repair work on this product must be
performed by a trained technician – no user-serviceable parts inside!
In all drawings below, the default jumper settings are marked in black.
Impedance setting for the VIDEO input (BNC socket, not used).
Default setting: hi-Z.
Impedance setting for the WCLK IN input (BNC socket).
Default setting: hi-Z; when changing the jumper to position P9-P10,
the input impedance is 75 Ω.
Not used.
Configuration for the WARN relay contact output.
WARN is active if an internal supply has a malfunction, provided that
two units are linked together or a second power supply unit is installed.
Jumper set to P25-P26: Make contact (default setting); jumper set to
P26-P27: Break contact.
Polarity inversion of the word clock outputs 4...6 if jumper is set to
INV (i.e. P38-P39); Default setting: NORM (P29-P39).