1.3.3 Connector Field

AES OUT 1-4
AES OUT 5-8
AES OUT 9-12
AES OUT 13-16
[4]
[1] Mains ~ 100 – 240 V
[2] AES IN 1-4
[3] AES IN
[4] AES OUT 1-...
[5] AES OUT
[6] VIDEO IN
[7] WCLK IN
[8] WCLK OUT
[9] ALARM
[10] REDUNDANCY LINK
[11] AES IN AUX 1-4
[12] DISTR. MODE
E 1/4 Come in!
[2]
[11]
AES IN 1-4
AES IN AUX 1-4
DISTR MODE
WCLK OUT
[12]
Connector for socket IEC 320/C13.
Supply voltage range 100...240 V
mains frequency 50...60 Hz.
For connecting to the mains, please consult the Safety section at the
very beginning of this manual.
Inputs for four digital input signals according to AES/EBU, with a fe-
male 15-pin D-type connector.
Input for sync signal with female XLR socket. Depending on the DIP
switch setting (see section 3.1), this input signal can be routed to the
outputs 1...4.
Outputs for 16 digital output signals according to AES/EBU, with four
male 15-pin D-type connectors.
Sync output with male XLR socket, hard-wired to the AES IN sync
signal input (XLR).
BNC socket; no function.
Word clock input, BNC socket, 75
Word clock outputs, 6 BNC sockets.
Alarm outputs watching the AES/EBU inputs 1...4 and the power sup-
ply; female 9-pin D-type connector.
Link socket for redundancy connection to a second unit, with female
15-pin D-type connector.
Optional inputs for four digital redundancy input signals according to
AES/EBU, with a female 15-pin D-type connector.
DIP switch bank with eight switches for basic settings, as routing se-
lection (refer to section 3.1).
[9]
[10]
ALARM
REDUNDANCY LINK
WCLK IN
[7]
VIDEO
OUT
IN
[6]
[5]
[3]
(without voltage selector);
AC
termination jumper-selectable.