Photoelectric Sensors
Red light diffuse reflective with background suppression
BOS 12M-...-RF11/RH12-S4
Product informationen
Fig. 1: BOS 12M-..-RH12-S4
Fig 2: BOS 12M-..-RF11-S4
These photoelectric sensors have the following features:
Optical filters for excellent ambient light rejection
Strong light sources for long ranges
Highly visible light spot for ease of alignment
Rugged housing
BOS 12M-PSV-RH12-S4
Order code: BOS01ZR
Switching output: PNP, N.O. and error output
Range: 25...100 mm
BOS 12M-PA-RH12-S4
Order code: BOS01ZU
Switching output: PNP, N.O. and N.C.
Range: 25...100 mm
BOS 12M-NA-RH12-S4
Order code: BOS0230
Switching output: NPN, N.O. and N.C.
Range: 25...100 mm
BOS 12M-PSV-RF11-S4
Order code: BOS01ZW
Switching output: PNP, N.O. and error output
Range: 50 mm
BOS 12M-PA-RF11-S4
Order code: BOS01ZT
Switching output: PNP, N.O. and N.C.
Range: 50 mm
BOS 12M-NA-RF11-S4
Order code: BOS022Z
Switching output: NPN, N.O. and N.C.
Range: 50 mm
1
english
Safety notes
These photoelectric sensors may not be
used in applications where personal safety
depends on proper function of the devices
(not designed in accordance with EU
Machinery Directive). Read these operating
instructions carefully before putting the
device into service.
Exempt Group according to IEC 62471.
DO NOT LOOK INTO THE LIGHT BEAM!
Danger of glare and irritation!
The sensor must be installed as to prevent
a direct line of eyesight to the llght source,
even during operation.
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
In our EMC Laboratory, which is accredited by the DATech
for Testing of Electromagnetic Compatibility, proof has
been documented that these Balluff products meet the
EMC requirements of the harmonized standard
EN 60947-5-2.
Display and operating elements
Fig 3:
Display and operating elements
(Potentiometer only with BOS 12M-..-RH12-S4)
Green LED power on/short circuit indicator
LED on: the sensor is operating.
LED flashes: short circuit on the output.
LED off: the sensor is not ready for operating
Yellow LED output signal/Error indicator
LED on: sufficient light at the receiver
LED flashes: insufficient light at the receiver
LED off: no light at the receiver
Potentiometer (only type RH12)
Used for setting the switch point of the background suppression.
www.balluff.com
Installation
CAUTION
Danger of glare and irritation!
Directly looking into the light beam can lead to glare and
irritation.
Do not look into the light beam!
BOS 12M-..-RH12-S4
Fig. 4:
Dimensions
BOS 12M-..-RF11-S4
Fig.:
Dimensions