INSTALLATION AND MAINTENANCE BOOK (TECHNICAL STAFF)
Introduction
'TWIN FLOW"' family of hand dryers offers the technical features as follows:
Automatic operation. Drying cycle starts when putting hands in. Two couple of IR
sensors detect hands introduction.
Dryer is a class I (earthed) electrical insulation device.
Drying process is based on powerful air curtains which remove water from hands.
Hand dryer has no heating element.
Speed of air can be adjusted in order to achieve an optimum balance between drying
power and noise level.
Light leds on top supply some information referred to the status of hand dryer.
Maximum time of continuous operation is T max = 30 sec.
Water from hands is collected in a removable tank which may be emptied and cleaned.
An HEPA filter is incorporated in the aspiration area whose state should be reviewed
periodically. The place of fitting the air inlet filter allows easy removal and replacement.
Optionally, in the aspiration area, an air-freshener can be incorporated.

Installation

ONLY A QUALIFIED TECHNICIAN CAN INSTALL, ADJUST AND MAINTAIN THIS HAND
The installation of the appliance is only allowed on fixed wiring.
Means for disconnection of the mains with contact separations at least 3 mm (0.12") must be
incorporated in the fixing wiring.
The installer must make sure that the electric system is grounded in accordance with the law in
force.
Make sure that the electric system has a high-sensitivity breaker I n ≤ 0.03 A.
Make sure that the machine is disconnected from the electric power supply, before performing
maintenance operation.
To install the hand dryer follow the pictures contained in the figure 2.
The hand dryer must be fitted to the wall by using the upper metal plate (support) which is
supplied.
DRYER.
-13-
www.all-care.eu