Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - Monacor PA-4040MPX Bedienungsanleitung

5-kanal-mischpult
Vorschau ausblenden Andere Handbücher für PA-4040MPX:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
14
230 V~/50Hz
USE ONLY WITH A 250V FUSE
15
5.2 Adjusting the volume and the sound,
switching the input signals
to the zones
1) Prior to switching on the mixer for the first
time, set the four zone controls LEVEL (11)
to zero to prevent an excessive volume at
the beginning . Then switch on the unit with
the POWER switch (13) . The POWER indica­
tor (12) lights up .
2) For basic setting of the input channels
a) set all controls GAIN (1), TREBLE and
BASS (2) to mid­position,
b) set all controls LEVEL (3, 11) to zero,
c) unlock all buttons ZONE SELECTOR Z 1
to Z 4 (4) .
3) Turn up the control LEVEL (3) of the input
which is to be heard at highest volume (e . g .
for an nounce ments) to approx .
maximum value . With the buttons ZONE
SELECTOR (4), switch the input signal to the
zones where it should be heard .
4) Switch on the power amplifiers for the
speakers and adjust the desired volume for
each zone with the zone controls LEVEL (11) .
The level indicators (9) show the volume of
the zones . The top red LED should light up
with passages of highest volume for a short
time only . If it lights up for a longer time,
turn back the corresponding zone control
LEVEL .
If the volume of the zones cannot be
adjusted in an optimum way because the
input signal is too low or too high, readjust
the input level with the corresponding con­
trol GAIN (1) or LEVEL (3) .
5) Adjust the sound with the corresponding
controls TREBLE and BASS (2) . If required, re­
adjust the volume with the control LEVEL (3) .
6) For feeding further input signals to certain
zones, press the corresponding buttons
ZONE SELECTOR (10) . With these buttons
the zones may be configured differently .
Example:
TEL. PAGING
PRIORITY
S701
ON
OFF
17 18 19
MIX OUT
MONITOR
PRIORITY TEL. PAGING
1 W 8 Ω
G
+
-
+
T
16
24V / 600 mA
+
-
T315 mAL
– The announcements of input CH 1 are to
be heard in all zones .
 Press the buttons Z 1 to Z 4 of CH 1 .
– The announcements of input CH 2 are to
be heard in zones 1 and 4 only .
 Press the buttons Z 1 and Z 4 of CH 2 .
– The background music of CH 4 is to be
heard in zones 1 and 2 .
 Press the buttons Z 1 and Z 2 of CH 4 .
– The background music of CH 5 is to be
heard in zones 3 and 4 .
 Press the buttons Z 3 and Z 4 of CH 5 .
7) Adjust the volume and the sound of further
input signals with the controls LEVEL (3),
TREBLE and BASS (2) . Turn the controls
LEVEL of the inputs not used to zero .
5.3 Muting the inputs CH 2 to CH 5
of the
2
3
for an announcement
If a switch is connected to the terminals PRIOR­
ITY (19), the inputs CH 2 to CH 5 can be muted
at the same time by closing the switch . Thus,
e . g . an important announcement can be heard
via the input CH 1 without interference by other
input signals .
5.4 Monitoring the zone signals
Press down the buttons MON (10) of the PA
zones whose signals are to be monitored . Ad­
just the volume for the monitor speaker con­
nected to the terminals MONITOR (18) with the
control MONITOR (8) and the volume for the
headphones with the control PHONES (6) . The
signal for the monitor speaker is shown by the
level indicator (5) .
Notes:
1 . The volume for the headphones and the monitoring
speaker also depends on the zone controls LEVEL
(11) . When a control is set to zero, the signal of
the corresponding zone cannot be monitored even
if the button MON is pressed .
2 . The buttons MON are also used to switch the
zone signals to the output MIX OUT (17) – see
chapter 4 .7 .
MONITOR MIX OUT
Jumper S701
Priority for the inputs CH 1 and TEL� PAGING
20
R
G
21
22
1
2 3 4
DIP
ON
23
24
L
L
25
R
R
CH 3
24
LINE OUT BAL./UNBAL.
LINE OUT BAL./UNBAL.
ZONE 1
G
+
ZONE 2
G
+
25
CH 1
26
LINE OUT BAL./UNBAL.
LINE OUT BAL./UNBAL.
ZONE 3
G
+
ZONE 4
G
+
CH 2
6

Specifications

Number of
input channels: � � � � � � � �5
Number of zones: � � � � � �4
Inputs
Input sensitivity/ impedance; connection
CH 1 – CH 3: � � � � � � � �5 mV/ 4 kΩ (Mic)
Phantom power: � � � � �15 V
CH 4, CH 5: � � � � � � � � �100 mV/ 30 kΩ (line);
TEL� PAGING: � � � � � � �40 mV – 1�5 V/ 5 kΩ;
Outputs
Speaker
MONITOR: � � � � � � � �8 Ω, 1 W
Line outputs
ZONE 1 – 4: � � � � � � �1�7 V, bal�
MIX OUT: � � � � � � � � �4 V, unbal�
Frequency range: � � � � � � �50 – 17 000 Hz
THD: � � � � � � � � � � � � � � � �< 1 %
S / N ratio
Mic: � � � � � � � � � � � � � �> 65 dB
Line: � � � � � � � � � � � � � �> 75 dB
Tone control for the inputs CH 1 – CH 5
Bass: � � � � � � � � � � � � � �±10 dB / 100 Hz
Treble: � � � � � � � � � � � � �±10 dB / 10 kHz
Power supply
Mains operation: � � � � �230 V/ 50 Hz
Power consumption: �20 VA max�
Emergency
power supply: � � � � � � �24 V (⎓)
Power consumption: �600 mA
Ambient temperature: � � �0 – 40 °C
Dimensions (W × H × D): �482 × 133 × 220 mm,
Weight: � � � � � � � � � � � � � �4�5 kg
Subject to technical modification .
All rights reserved by MONACOR
GmbH & Co. KG. No part of this instruction manual
may be reproduced in any form or by any means for
any commercial use.
switchable to
100 mV/ 10 kΩ (line);
XLR / 6�3 mm jack, bal�
RCA, unbal�
screw terminals, unbal�
3 RS
®
INTERNATIONAL
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis