Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning And Maintenance; Cleaning The Heating Element - EuroLite N-150 Bedienungsanleitung

Smoke-machine
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Control channel 4 - Adjusting the intervals (only in Timer-mode)
Data:
255
230-254
205-229
180-204
155-179
130-154
105-129
80-104
55-79
30-54
5-29
0

CLEANING AND MAINTENANCE

We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the escape nozzle frequently from smoke fluid residues. Clean out debris with vinegar and a pipe
cleaner, making sure that the hole is free of clogs.

Cleaning the heating element

The heating element should regularly be cleaned every 30 operational hours in order to avoid clogging. Use
smoke-machine cleaner available at your dealer.
Procedure:
Fill cleaner into empty tank. Run the machine several times in a well-ventilated room only. The number of
repititions depends on the pollution level of the vaporizing elements. After use clean all remaining cleaner
and rinse the tank thoroughly with distilled water.
The EUROLITE smoke fluids we recommend are non-hazardous to the environment and can be disposed of
via the sewage system.
There are no servicable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
If the fuse interrupts, please reset the breaker.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device will be damaged, it has to be replaced by authorized dealers only in
order to avoid hazards.
Time (second):
200
190
170
151
131
112
92
73
53
33
13
1
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
24/47
51701970_V_1_3.DOC

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis