Herunterladen Inhalt Inhalt Diese Seite drucken

Connection With The Mains; Operation - EuroLite N-150 Bedienungsanleitung

Smoke-machine
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Before taking into operation for the first time, the installation has to be approved by an expert!

Connection with the mains

Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!

OPERATION

Switch the device on via the power switch. Connect the remote control with the Remote Control-socket.
After a certain warm-up time, the device is ready to operate. When the machine is ready for fogging, the
display shows "Ready To Fog". By operating the smoke switch on the remote control the smoke emission
starts. It may happen that the stand-by lamp turns off and the smoke emission stops. In this case the device
is heating up again and will be ready to operate in approx. 1-2 min. This process guarantees an appropriate
vaporization temperature and the best smoke emission possible. The temperature is regulated by a high
quality thermostat.
The remote control's interface allows the operator to customize fog machine functions by adjusting fogging
duration, interval and volume. Its LCD displays current operating parameters, which are automatically stored
in non-volatile memory, allowing the machine to be powered down without losing function
settings.Instructions below:
down to "0". After that, the fog emission is triggered at the volume adjusted under "Timer Out". The duration
DANGER TO LIFE!
International
L
N
Description of the elements:
(1) LCD-Display
(2) Function-key
(3) Up-/Down-keys
(4) Timer-key
(5) Volume-switch
(6) Manual-key
After the machine starts heating up, the display shows "Warming
Up". When the machine is ready for fogging, the display shows
"Ready To Fog".
Via the Function key, you can adjust the desired settings. After
pressing the Function key once, the display shows "Interval Set".
Adjust the interval between each fog emission (within the range of
1 to 255 seconds) by means of the Up-/Down keys. By pressing
the Function-key twice, the display shows "Duration Set". Adjust
the duration of each fog emission (within the range of 1 to 20
seconds) by means of the Up/Down keys. Under the menus "Timer
Out" and "Volume Out" you can adjust the output volume by
means of the Up/Down keys. The menu "DMX Add" refers to
adjusting the DMX address for DMX control or synchronization.
Adjust the desired DMX-address by means of the Up/Down keys.
Press the Timer key to activate the timer function. The display
shows the adjusted interval and the device counts the seconds
20/47
51701970_V_1_3.DOC

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis