PROBLEM SOLVING
Problem
Possible cause
Device is plugged in, LCD
Problem with the con-
display is empty.
nection.
Device does not heat, E7
Device signals emergency,
or E9 is flashing on the
temperature sensor has
display panel.
been damaged.
Controller has been incor-
rectly installed on the
heating element.
Device does not heat, E6 is
Device signals emergency,
flashing on the LCD panel.
overheating.
Device is heating although
Electronics damage.
it has been turned off with
the
button.
If the problem persists, please contact your local distributor.
KTX 4
Solution
Check the power wire
connection, plug and the
socket.
Disconnect the device
completely and wait until
the radiator cools down,
after that reconnect the
device.
Check if the heating ele-
ment head is hidden com-
button – turns the device on / off
pletely. Turn the screw
button – TIMER programming
off, press the controller
Buttons
towards the radiator and
sign
twist the screw again.
icon – HEATING indicator
icon – icon indicating connection to a transmitter
Check if the radiator is
properly filled with the
Heating element unit heats the radiator that it is installed in and precisely controls its
heating agent.
temperature at the same time. Buttons
Disconnect the device
the
icon indicates that the radiator is being preheated.
completely and wait until
the radiator cools down,
Turning the device on does not mean that it uses the same maximum power for the
after that reconnect the
whole time it is on. On turning the device on, it operates with the nominal power for
device.
a short period of time in order to heat up the radiator to the set temperature. After
that it turns itself on and off periodically, using only as much energy as it is required
to maintain the set temperature of the radiator for current external conditions (see:
Actual working time meter).
Construction of the heating element unit as well as physical characteristics of the heating
agent cause that the bottom pipes (especially the two at the very bottom of the radiator)
may have a lower temperature than the remaining parts of the radiator – this is a normal
phenomenon.
KTX 4 controller installed on the SPLIT heating element is the basic configuration of this
type of heating element unit which allows use of all the basic features of the device (see:
Local mode operation).
KTX 4 controller can also cooperate with an external wall-mounted transmitter (ie. DT-IR
type), which adds additional features to the basic set (see: Remote mode operation).
and
– temperature regulation or modification of TIMER settings – numeric
and
are used to regulate temperature whilst