Herunterladen Inhalt Inhalt Diese Seite drucken

nedis KAIP110CBK1 Anleitung Seite 5

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 12
Showing
Cause and handle method
E3
Voltage surge protection. When the input voltage is over 275 V, the cooker will
stop working and show "E3". It will work again when the voltage returns to the
145-275 V range.
E4
Low voltage protection. When the input voltage has already dropped below
145 V, the unit will stop working and show "E4".
It will work again when the voltage returns to the 145-275 V range.
E5
The sensor of the top plate was open or has short circuited.
The unit will stop working and show "E5". Check all inner parts and replace if
necessary.
E6
The sensor of the IGBT was open or has short circuited. The cooker will stop
working and show "E6". Check all inner parts and replace if necessary.
E7
The top plate has overheated and the cooker has stopped working. Allow to
cool.
Specifications
KAIP110CBK1:
Power rate:
Voltage:
KAIP111CBK1:
Power rate:
Voltage:
KAIP112CBK2:
Power rate:
Voltage:
2000 W
230 V AC~50 Hz
2000 W
230 V AC~50 Hz
2 x 1700 W
230 V AC~50 Hz