Technical Data
Supply circuit (A1, A2)
Operating voltage U
AC/DC 24 V
B
Residual ripple DC Uss
Rated power
Peak current I
Peak
Operating voltage U
AC 42 - 48 V
B
Rated power
Operating voltage U
AC 115 - 120 V
B
Rated power
Operating voltage U
AC 230 V
B
Rated power
Fuse
Rated frequency AC
Output circuit (S11, S21)
Output voltage
Short-circuit behavior
Input circuits S12 and S52/S22
Input voltage U
e
Input current I
e
Input peak current I
e,peak
Conductor resistance
Release time t
R
Recovery time t
W
Interrupt time of U
(test pulses), t
e
TP
Period of interrupt time
Synchronous time t
S
Input circuit S34
Input voltage U
e
Input current I
e
Input peak current I
e peak
Conductor resistance
Response time t
A1
Response time t
A2
Ready time t
B
Minimum ON time t
M
Interrupt time of U
(test pulses), t
e
TP
Period of interrupt time
Output circuit
Continous current I
n
Switching voltage U
n
Switching load
Contact equipment
SNA 4044K, SNA 4064K
SNA 4043K, SNA 4063K
Contact material
Utilization category acc. EN 60947-5-1
Fuse
Mechanical endurance
General data
Creepage and clearance between circuits
Rated surge voltage
Overvoltage category
Contamination level
Rated voltage
Test voltage U
50 Hz
eff
Protection degree EN 60529 (housing / terminals)
Ambient temperature working range / storage range
Weight DC devices / AC devices
Terminals and connection
Single-core or finely stranded
Stripping length
Finely stranded with wire-end ferrule to DIN 46228
Max. tightening torque
*
see diagram 1
(
)
4
min.
typ.
max.
20.4 V
--
26.4 V
--
--
2.4 V
--
1.6 W / 2.9 VA
--
--
--
1.5 A
AC 35.7 V
--
AC 52.8 V
--
2.3 W / 2.6 VA
--
AC 97.8 V
--
AC 126.5 V
2.2 W / 2.5 VA
AC 195.5 V
--
AC 253 V
2.1 W / 2.4 VA
T 0.5 A (time lag)
50 Hz
--
60 Hz
--
--
DC 40 V
absolutely short-circuit proof
19.2 V
--
26.4 V
--
25 mA
--
--
--
100 mA
--
--
25 Ω
--
--
10 ms
--
--
750 ms
--
--
1 ms
25 ms
--
--
--
--
19.2 V
--
26.4
--
5 mA
--
--
--
50 mA
25 Ω
--
--
--
150 ms
350 ms
--
50 ms
100 ms
350 ms
--
--
100 ms
--
--
--
--
1 ms
25 ms
--
--
--
--
8 A
*
(
--
--
300 V
--
--
2000 VA
4 Enabling paths (NO, positively driven)
3 Enabling paths (NO, positively driven)
1 Signalling path (NC, positively driven)
AgSnO
2
AC-15: Ue AC 230 V, Ie 5 A
DC-13: Ue DC 24 V, Ie 5 A
max. 8 A (utilization category gG or a circuit-breaker tripping characteristic B or C)
10
7
acc. EN 60664-1
4 kV
III
3 external, 2 internal
AC 300 V
2 kV
IP 40 / IP 20
-25°C to +65°C / -25°C to +70°C
0.21 / 0.25 kg
screw-type terminals
spring-type terminals
1 x 0.2 - 2.5 mm² / 2 x 0.2 - 0.75 mm²
2 x 0.2 - 1.5 mm²
max. 8 mm
1 x 0.25 - 2.5 mm² / 2 x 0.25 - 0.5 mm²
2 x 0.25 - 1.5 mm² (trapezoid crimping)
0.5 to 0.6 Nm
--
Funktionsdiagramm automatischer Reset
Function diagram for automatic reset
Diagramme de fonctionnement avec démarrage (reset) automatique
SNA 4043K
SNA 4044K
t
Ansprechzeit
A
t
Testpulszeit
TP
t
Rückfallzeit
R
t
Bereitschaftszeit
B
t
Wiederbereitschaftszeit
)
W
t
Mindestbetätigungszeit
M
Response time
Temps de réponse
Test pulse time
Temps d'impulsion test
Release time
Temps du retour du relais
Standby time
Temps de disponibilité
Recovery time
Temps de recouvrement
Minimum ON time
Temps minimal d'actionnement
9

Werbung

loading

Diese Anleitung auch für:

Sna 4043kSna 4044kSna 4064k