SETTINGS FOR OPERATION OF THE HEATING SYSTEM AND WARM WATER HEATER
For more information on the settings on the panel, please refer to the "Control Panel" section.
HEATING WITH CONTINUOUS OPERATION OF THE CIR-
CULATION PUMP WITH 230 V HEATING CARTRIDGE
1. Slide the circulation pump switch to position (J).
2. Slide the LPG switch to position (E).
3. Slide the heating cartridge switch to the desired output position (B, C or D).
In the illustration, an output of 2100 W has been selected.
4. Adjust the temperature to the desired level (5-30°C) using the knob of the
room thermostat (K).
NB! Continuous operation of the 12 V circulation pump reduces the service life
of the motor considerably.
HEATING WITH CONTINUOUS OPERATION OF THE
CIRCULATION PUMP WITH LPG BOILER
1. Open the LPG shut-off valve.
2. Slide the circulation pump switch to position (J).
3. Slide the LPG switch to position (F).
4. Slide the heating cartridge switch to position (A).
5. Adjust the temperature to the desired level (5-30°C) using the knob of the
room thermostat (K).
NB! Continuous operation of the 12 V circulation pump reduces the service life
of the motor considerably.
HEATING WITH CONTINUOUS OPERATION OF THE
CIRCULATION PUMP WITH 230 V HEATING CARTRIDGE
AND LPG BOILER
(Use only when electricity or gas alone is not sufficient)
1. Open the LPG shut-off valve.
2. Slide the circulation pump switch to position (J).
3. Slide the LPG switch to position (F).
4. Slide the heating cartridge switch to the desired output position (B, C or D).
In the illustration, an output of 2100 W has been selected.
5. Adjust the temperature to the desired level (5-30°C) using the knob of the
room thermostat (K).
NB! Continuous operation of the 12 V circulation pump reduces the service life
of the motor considerably.
SWITCHING OFF THE LPG BOILER, HEATING
CARTRIDGE AND CIRCULATION PUMP
1. Slide all three switches on the control panel to the 0-position (H, E, A).
2. Close the main switch to the heating system if the vehicle will not be used.
If the main switch is not closed, the boiler will remain in the stand-by
position and use a small amount of electricity.
3. Close the LPG shut-off valve.
IF THE RED LED-LIGHT COMES ON
The boiler is fitted with an ionised flame sensor. This means that if the flame
goes out for some reason, the electronics will attempt to re-light it. If the flame is
not re-lit within ten seconds, the solenoid valve switches off the gas supply, the
electronics are blocked and the red LED (G) on the control panel is switched on.
The electronics must be reset before the boiler can be started.
Resetting from the blocked position
1. Slide the LPG switch to position (E). The LED (G) will go out.
2. Wait approx. 30 seconds while the electronics resets the block.
3. Slide the LPG switch to position (F). The electronics will once again attempt
to start the boiler.