Abnormal indications during use
The BCV01 indicates various states using the remaining battery capacity indication.
Indicator lamps
: On
Battery 1
1. BCV01 malfunction
When the three indicator lamps for Battery 1 and the three indicator lamps for Battery 2 light alternately, the
BCV01 may have malfunctioned. Contact your Makita dealer or nearest Makita Sales Center to request inspection
and/or repair.
2. BCV01 protective function
When a product is used continuously at a high load, the motor may stop automatically. This is due to the BCV01's
protective function, and is not a malfunction. If the product does not operate even when the product switches are
operated, stop use, disconnect the product and batteries from the BCV01, and let the BCV01 cool down.
. Battery protective function
The batteries have an internal protective function that automatically stops power output in order to extend the bat-
tery life. When the following states occur during product use, the motor stops automatically, but this is due to the
battery's protective function, and is not a malfunction.
When the battery temperature rises above a certain level, the motor stops automatically, and remains stopped
even when the switches are operated. In these cases, stop battery use, remove the batteries from the BCV01, and
allow the batteries to cool or charge the batteries.
When the battery capacity becomes low, the product's motor stops automatically. If the product does not operate
even when the switches are operated, remove the batteries from the BCV01 and charge the batteries.
4. BCV01 abnormally high voltage detection
When the BCV01 detects an abnormally high battery voltage, the motor stops automatically. This is due to the
BCV01's protective function, and is not a malfunction. In these cases, the motor remains stopped even when the
switches are operated.
Remove the batteries from the BCV01, and use different batteries with normal voltage.
NOTE
When the product stops automatically without any BCV01 indication
When the product enters an overload state, power output stops automatically in order to extend the battery life. This
is due to the battery's protective function, and is not a malfunction. In addition, in these cases the BCV01 does not
indicate anything, but this is not a malfunction. When this happens, release the switch, and remove the cause of the
overload. The product can then be used again by operating the switch again.
: Off
: Blinking
Battery 2
Indication contents
The BCV01 may have malfunctioned.
The protective function operated.
The protective function operated.
Charge the battery.
The BCV01 detected an abnormally high voltage.