Supply voltage
Operating Temperature
Resistive load
Resistive load inductive
Temperature Control
Control Span
Housing / Protection
For wall mounting or as built in Thermostat.
Alternative Floor sensor, Room sensor or both.
Sensor values
0°C
15°C
+25°C
+40°C
Punctual Fault finding:
This may only be executed by an authorised installer.
Checking possible faults:
Check the power at the terminal box L and N.
Tighten the screws in the terminal box.
Measure the resistance in the heating cable
and calculate the effect.
180 - 250 V ˜ 50 Hz
+0°C to +40° C
250 V 16 A
ϕ
Cos
= 0,3 Max. 1 A
+5°C to +35° C
1°C
IP 21
32 kOhm
15,7 kOhm
10 kOhm
5,3 kOhm
Driftspænding
Temperaturbegrænsning
Ohmsk belastning
Induktiv belastning
Temperatur område
Temperatur afvigelse
Kapslings klasse
Termostat til montage på væg eller i vægdåse.
Gulvføler, rumfølerfunktion eller kombineret gulv-
og rumfølerfunktion
Føler modstand
15°C
+25°C
+40°C
Punktvis fejlfinding:
Må kun udføres af en autoriseret el-installatør.
Kontrol af mulige fejl:
Kontroller spændingen mellem klemme L og N.
Spænd skruerne på klemmerne.
Mål modstanden i varmekablet og beregn
effekten.
180 - 250 V ˜ 50 Hz
+0°C to +40° C
250 V 16 A
ϕ
Cos
= 0,3 Max. 1 A
+5°C to +35° C
1°C
IP 21
0°C
32 kOhm
15,7 kOhm
10 kOhm
5,3 kOhm