Technical data of the SLK 1 to SLK 6 Laboratory hot plates
CE sign:
Country of origin:
Display:
Stirring using:
magnetic stirrer
Temperature control:
Connections:
Temperature sensor:
Mains:
Safety standards:
Power supply:
Casing material:
Climate:
Ambient temperature:
Relative humidity:
Overview of the four SCHOTT Laboratory hot plates:
Laboratory hot plate types
Dimensions
approx. w x h x d [mm]
Glass-ceramics
approx. w x d [mm]
Glass-ceramics floor space
approx. [mm]
Radiator type
Heating output
Stirring function
Temperature control
Weight, approx. [kg]
th
15. Januar, January 15
, 15 Janvier 2001
AGQSF 0000-A070-01/040618
Electromagnetic compatibility according to the Council Directive 89/336/EMC;
generic emission according to standard EN 50 011
generic immunity according to EN 50 082, part 1
low-voltage directive according to the Council Directive 73/23/EMC,
last modified by the Council Directive 93/68/EMC
made in Germany
7-segments light-emitting diodes display (LED), height 13 mm
control-temperature display with SLK 6 + SLK 2-T Laboratory hot plates: 3-digit
Stirring speed adjustable in 9 stages from approx. 100 to > 1 000 U · min
from room temperature to 199 °C in increments of 1 - K ,
temperature stability: ± 2 K ... ± 5 K
depending on vessel, volume of the liquid and ambient temperature
2 x 4 mm sockets for Pt 1000 Resistance Thermometer
integrated Europe-type plug with fuse: Cold-device plug DIN VDE 0625
EN 60 320 , IEC 320 / C 14 / C 18 (DIN 49 457 B9),
The Laboratory hot plates correspond to the following safety standards:
EN 60 335, Part 1 and EN 60 335, part 6;
and EN Device of Protective Class I, manufactured and tested according to
protective measures for electric heating apparatus;
not suitable for environment with an explosion hazard
Mains: 230 V~, 50 / 60 Hz or 115 V~, 50 / 60 Hz (to be specified on the order)
Composite HUP EJ 27 075 (SMC on unsaturated polyester-resin basis)
+ 10 ... + 40 °C for operation and storage
according to EN 61 010, Part 1:
maximal relative humidity 80 % for temperatures up to 31 °C,
linearly decreasing to 50 % relative humidity at a temperature of 40 °C
SLK 1 / SLK 2
295 x 110 x 390
280 x 280
∅ 165 with SLK 1
∅ 200 with SLK 2
infrared
1 200 with SLK 1
1 800 with SLK 2
no
no
3.6
SCHOTT Instruments GmbH
Hattenbergstraße 10
55122 Mainz
Deutschland, Germany, Allemagne
SLK 2-T
295 x 110 x 390
445 x 110 x 390
280 x 280
430 x 280
∅ 200
∅ 165 and
infrared
infrared + foils
1800
1 200
no
yes
yes
yes
4.0
6.2
State January 15th, 2001
-1
SLK 6
145 x 145
/ 500