Overload Protection: Fuse 1: F 400mA/690V
Fuse 2: F 10A/690V
Max. Input Current: 10A (For inputs > 2A : measurement duration
< 10 secs, interval > 15 minutes)
Frequency Range:
40Hz ~ 400Hz
Response:
Average, calibrated in rms of sine wave
400mV
Max. Voltage Drop:
Note: The 10A range is specified from 20% to 100% of range.
Frequency
Range
Resolution
10Hz
0.01Hz
100Hz
0.1Hz
1kHz
0.001kHz
10kHz
0.01kHz
100kHz
0.1kHz
Input Voltage: 1Vrms -20Vrms

Duty Cycle

Range
Resolution
5% ~ 99%
0.1%
Input Voltage: 3Vp-p ~ 10Vp-p
Overload Protection: 600V DC/AC rms
Resistance
Range
Resolution
400Ω
0.1Ω
4kΩ
0.001kΩ
40kΩ
0.01kΩ
400kΩ
0.1kΩ
4MΩ
0.001MΩ
40MΩ
0.01MΩ
Capacitance
Range
Resolution
40nF
0.01nF
400nF
0.1nF
4µF
0.001µF
40µF
0.01µF
100µF
0.1µF
For the ranges  400nF, use Relative mode (REL) to subtract the stray capacitance of the
test leads and the Meter.
For the range of 100µF, wait about 30 secs for the reading to settle.
19
Accuracy
± (1.0% + 3)
± (0.8% + 3)
Accuracy
1 Hz ~ 10kHz: ± (2% + 5)
> 10kHz: not specified
Accuracy
± (1.0% + 5)
± (1.0% + 3)
± (1.8% + 5)
Accuracy
± (4%+20)(REL)
± (3%+5)(REL)
± (4% + 5)
± (8% + 5)