Herunterladen Diese Seite drucken

Maintenance; Spare Parts And Accessories; Warranty; I/O Configuration And End Of Cycle Switch - Techcon Systems TS250 Benutzerhandbuch

Precision dispensers
Vorschau ausblenden Andere Handbücher für TS250:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
8

MAINTENANCE

The dispenser is designed and built to be relatively maintenance free. To assure
trouble free operation, the following recommendations should be followed:
1.
Make certain air supply is clean and dry.
2.
Avoid turning barrels upside down or laying barrel so that material may
run through air line to internal components.
3.
Avoid connecting the unit to excessive moisture or solvent saturation.
4.
Avoid connecting air supply exceeding 100 psi (6.9 bar) for the TS250
and 15 psi (1.03 bar) for the TS255.
5.
Use only Amyl Alcohol to clean outside surface of the main housing.
6.
Use only soft cloth to clean the LCD.
9

SPARE PARTS AND ACCESSORIES

For TS-3xx/2xx spare parts and accessories information, please visit the TS-3xx/2xx
User Guide webpage at http://www.okinternational.com
10 LIMITED WARRANTY
OK International warrants this product to the original purchaser for a period of one
(1) year from date of purchase to be free from material and workmanship defects but
not normal wear-and-tear, abuse and faulty installation. Defective product or
subassembly and components under warranty will be repaired or replaced (at OK
International's option) free of charge. Customer with defective product under
warranty must contact the nearest OK International office or distributor to secure a
return authorization prior to shipping the product to the assigned OK International
authorized service center. For nearest OK International office or distributor contact
information, please visit www.okinternational.com. OK International reserves the
right to make engineering product changes without notice.
7

11 I/O Configuration and End of Cycle Switch

During a dispense cycle, an open collector circuit closes and remains closed while
the valve is
dispensing.
Pin 3 and 4 can be as feedback signal to synchronize with
other devices. Power from an external source is allowed to pass through the circuit
to operate a 5 to 24 VDC load. Power consumption must not exceed 250 mA. The
load could be a relay, solenoid, counter, LED, or any device that will operate within
a 5 to 24 VDC range and a maximum of 250 mA.
Note:
During the dispense cycle, pin 3 will be grounded. Please make sure the
external device (your machine that controls the dispenser/controller) has the
same ground as the TS250/255 controller.
Pin 1 (+)
Pin 2 (-)
End of Cycle Feedback
During dispensing cycle, Pin 3 is grounded (-)
End of dispensing cycle,
Pin 3
Pin 3 is not connected (opened)
Pin 4
When low pressure alarm is triggered, Pin 4 is grounded (-)
When low pressure alarm is turned off,
Pin 4 is not connected (opened)
Pin 5
To initiate a dispense cycle with
contact closure
Pin 6
Pin 5
Pin 7, 8, and 9 = Available
To initiate a dispense cycle with voltage
Chasis Ground
8

Quicklinks ausblenden:

Werbung

loading

Diese Anleitung auch für:

Ts255Ts350Ts355