Herunterladen Inhalt Inhalt Diese Seite drucken

Natural Stone Cladding - Konigshutte Cetus Anleitung

Vorschau ausblenden Andere Handbücher für Cetus:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
According to the (German) Federal Immissions
Control Act, it is forbidden e.g. to burn the follow-
ing fuels in stoves:
Moist wood or wood treated with wood pre-
servatives
Sawdust, chippings, grinding dust
Bark and chipboard waste
Slack coal
Other wastes
Paper and cardboard (except for igniting)
Straw

Natural Stone cladding

This natural stone cladding may not be overheat-
ed, as cracks could appear in the stone.
Use a maximum of 3 kgs wood or briquette (that
are 2 suitable logs or 1,5 briquettes) for heating.
As the cladding as a natural product comes from
a "grown" boulder, structure and colour scheme
may be very different.
The surface may be alterated under temperature
influence.
Please note before heating for the first
time
Remove all accessories from the ash pan and
combustion chamber first.
The odour given off by the evaporation of the
protective coating disappears after the stove has
been burning for several hours (ventilate the
room well).
The stove has a high quality temperature re-
sistant coat, which does not achieve its final
strength until the stove has been heated for the
first time.
- You should therefore never leave anything on
the stove and not touch the surfaces as the paint
coat could otherwise be damaged.
Igniting
Empty the ash pan if necessary and slide back
in.
Open the primary and secondary air controller.
Place the kindling material (ignition cubes and
kindling wood) as described and ignite it from the
top.
Place and ignite the kindling materials (paper,
ignition cubes, kindling wood, etc.).
Close the door to the combustion chamber so
that the kindling material can catch fire.
As soon as the kindling material has burned
down, put on 2 burnouts consisting of 3 kgs wood
ensuring that the temperature resistant coating
reaches its final firmness.
Using the air controller
Secondary air controller
The primary aire controller is located below the door
and the secondary air controller above the door.
Secondary air controller to the right ⇒ Open
Primary air controller pulled out
Primary air controller...
... OPEN
Ignition adjustment max. heating
output
... CLOSED
Nominal heat output with billet wood
... 1/10 OPEN Nominal heat output with wood
briquettes
... CLOSED
glow
As the secondary air also contributes to the cleanli-
ness of the glass pane, the secondary air controller
must always be moved in the direction of the open
position while the stove is lit.
As the performance of your stove is very much de-
pendent on the chimney draught, the primary air con-
troller has to be adjusted according to your own ex-
perience. Please note that you should not use your
stove if there is not an adequate air supply (slide
valve setting too low), as this causes the emissions
to increase.
Primary air controller
⇒ Open
9

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tucana

Inhaltsverzeichnis