Herunterladen Diese Seite drucken

AIRFORCE F129 60 TSL3 Montage- Und Gebrauchsanweisung Seite 10

Vorschau ausblenden Andere Handbücher für F129 60 TSL3:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
GB
INSTRUCTION ON MOUNTING AND USE
Check also the drawings on the initial pages with the alphabetical
and numerical references in the explanatory text.
Closely follow the instructions in this manual. We cannot
accept liability for any faults, detriment or fire damage to the
appliance due to non-compliance with the manual's
instructions. Installation and electrical connections must be
executed by a qualified technician. You should affix the hood
to a wall of sufficient weight-bearing capacity, so not to one
made of plasterboard. Do not install it inside a cupboard.
Installation
The cooker hood must be placed at a minimum distance of 65
cm from the cooking plane for electric cookers and 75cm for
gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater
distance, this has to be taken into account.
Do not tile, grout or silicone this appliance to the wall. Surface
mounting only. Do not fix chimney flue to furniture or fly over
shelves unless the chimney flue can be easily removed, in
case maintenance is ever required.
Use
The cooker hood is provided with an upper air exit B for
discharging fumes externally for models including chimney
flue C ( Suction Version A- exhaust pipe not supplied).
If cooking fumes and vapours cannot be externally discharged,
the cooker hood can be used in the recirculating version
F: the installation of 1 active charcoal filter F allows the
recirculation of fumes and vapours through the upper grid G.
Electrical connection
Make sure that there is a power socket near the hood and
that the system has a 30 mA differential. The mains voltage
must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it
does have a plug, connect the hood to an accessible
approved socket; or if it does not (connection direct to the
mains), fit an approved bipolar switch with a minimum
contact opening of no less than 3 mm (accessible). This
installation and electrical connection must be executed by a
qualified technician.
Operation
General notes: Any function can be activated by pressing
softly the button under the symbol.
A. ON/OFF light button: By essing this button the hood's
lights switch on.
4
3
2
1
B .
A .
B. ON/OFF motor button: By pressing this button the
extracting motor can be activated/stopped.
1.2.3.4. Speed regulator button: By progressing this button
the hood activates the selected extracting speed.
Funzione Timer: By pressing once again the Selectedspeed
button,the timer will last for 5 minutes. This function can be
applied to all 4 available speeds.
Grease filter saturation: After every 40 hours of use of the
hood, the button B or 3+4 indicator shows byflashing slowly
that the grease filters need to be washed.
Charcoal filter saturation: After every 120 hours of use of
the hood, the button B or 3+4 indicator by flasihing fast shows
that the charcoal filters need to be replaced.
Note: By pressing for at least 5 minutes the button 3+4 will
reset the filters saturation indicator.
Attention! This function should only be used after
performing the maintenance of the filters.
Automatic functioning through the heath sensor:
By pressing the button 1 2 at the same time, the hood
starts the automatic functioning. The indicators of the 4 speeds
will flash in sequence . After more or less 30 seconds the
temperature sensor will start the motor choosing the right
extracting speed.The speed will change according to the heath
coming from the hob.
By pressing B the manual functioning can be restored.
Always clean the glass of the control for a correct
functioning.
Maintenance
Prior to any maintenance operation ensure that the cooker hood
is disconnected from the electrical outlet.
Cleaning:
The cooker hood should be cleaned regularly internally and
externally.For cleaning use a cloth moistened with denatured
alcohol or neutral liquid detergents. Avoid abrasive detergents.
Warning: Failure to carry out the basic standards of the cleaning
of the cooker hood and replacement of the filters may cause fire
risks. Therefore we recommend observing these instructions.
Anti-grease Filter – must be cleaned once a month, with non
abrasive detergents, by hand or in dishwasher on low temperature
and short cycle.
When washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
Charcoal Filter - (only for filter version):
The active charcoal filters F are not washable nor regenerative.
It should be changed every 6 months in normal use.
The active charcoal filters capture unpleasant cooking odours.
Replacing lightbulbs
Warning! Prior to touching the light bulbs ensure they are cooled
down.
Led Light
If the lighting group LED does not work, please contact the
technical service center in order to replace the whole group.
6

Werbung

loading

Diese Anleitung auch für:

F129 90 tsl3