Herunterladen Inhalt Inhalt Diese Seite drucken

Desoutter ELS7-360-A4S Betriebsanleitung Seite 17

Vorschau ausblenden Andere Handbücher für ELS7-360-A4S:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 29
Error
6 red flashing lights Tool overheating. The tool
7 red flashing lights Battery voltage fault. The
8 red flashing lights Overcurrent on the power
At start-up, after
switch-off the white
LED, the LED
flashes 3 times (red
color)
(1 flash/second).
At start-up, after
switch-off the white
LED, the LED
flashes 8 times (red
color)
(3 flashes/second).
Permanent flashing
of the LED (red
color)
(6 flashes/second).
Permanent flashing
of the LED (red
color)
(3 flashes/second).
04/2014
Description
does not start or stops
instantaneously.
tool does not start or stops
instantaneously.
circuit. The hardware limit
has been reached. The
tool does not start or stops
instantaneously.
Backup configuration has
been restored.
Main configuration has been
restored from the backup
configuration.
The tool switched to default
setting.
All configurations have been
corrupted.
Tool blocked.
Validation / Action
The power requested is too big. Do not use
the tool as a drilling machine. If the fault still
appears, contact our customer service.
The fault means that the battery voltage is not
appropriate for the voltage announced in the
tool. Make sure that the tool is adapted for the
battery used. If the battery used is correct=>
contact our customer service.
This problem can result from a use requiring
a too big power for the tool. If the fault still
appears, the power stage is faulty => contact our
customer service.
The user is not affected by this issue.
The tool can be used without restriction.
This error appears if the backup configuration
has been restored after corruption.
User not affected by this issue during normal
work.
If the user was updating the configuration of
the tool with the Speed Setting Module, it is
recommended to check the speed of the tool.
This error appears if the main configuration has
been restored after corruption.
The tool can be used but only with the default
parameters.
Speed and counters may be affected.
It is recommended to check the parameters
with the Speed Setting Module. If the problem
persist when the battery is plugged in, it is
recommended to replace the electronic board.
This alarm appears if the memory chip is out of
order.
The electronic board must be replaced.
6159931420
Issue no : 10
Series : C
17 / 128

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis