Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications - Facom 711P.500 Bedienungsanleitung

Zangen-amperemeter für gleichund wechselstrom
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 8
!
Safety
Never carry out measurements on non-insulated wires with a
potential of over 600 V in relation to earth.
Never open the case on the ammeter clip before having first disconnected it from
any source of electricity.
Do not use the
711P.500

Technical specifications

Size
Weight
1 battery
Endurance
Indication that battery is running out
Capacity
Output signal
Measuring equipment impedance :
Operating temperature range
Storage temperature range
Relative humidity in use
Relative humidity in storage
Double insulation
Degree of pollution
Seal
Electrical safety
Degree of casing protection
Radiated field
Free fall
Vibrations
Impacts
Electric shocks
Electrostatic discharge
Rapid transients
Maximum dimensions
Comes with a 1.5 m cord with two 4 mm-diameter male plugs on the end, a 9 V
battery not fitted, an instruction manual and a guarantee leaflet.
Gap for wire
Green «on» indicator
light
Opening lever
Direction of direct current
Sealed 1.5 m cord
clip outside.
: 250 x 97 x 44 mm
: 440 g
: 9 volts
(type: 6LR61 - 6LF22 - NEDA 1604)
:120 hours with alkaline battery
: 60 hours with saline battery
: green indicator light flashes
:
600 A DC
:
1 mV, DC
≥ ≥ ≥ ≥ ≥ 1 MΩ Ω Ω Ω Ω
:
-10° to +65°C
:
-40° to +80°C
< 20 to 75% RH
:
< 80% RH
:
:
Installation category III
:
2
(per standard IEC 1010-1)
:
IP40
(per IEC 529)
:
(per standard IEC 1010-2-032)
:
(per standard IEC 529)
:
3 V/m
(per IEC 801-3)
:
1 m
(per IEC 1010)
0.75 mm
:
:
0.5 joules
:
3 kV
(per IEC 801.5)
:
4 kV class 2
:
1 kV
level 2, aptitude criteria B
: 30mm-Ø cable or 2 of 24mm-Ø cables
: Bar cross-section 50 x 10 mm
or
400 A AC
or
AC for 1 A, DC
and
≤ ≤ ≤ ≤ ≤ 100 pF
(up to 40°C)
(per IEC 68.2.6)
(per IEC 68.2.27)
(per IEC 1000-4-2)
Jaw
Anti-slip protector
On/off switch
Button to reset when
under direct current
GB
(600 A en crête)
or
AC
(IEC 1000-4-4)
5

Werbung

Inhaltsverzeichnis
loading