Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 36
No.
Error message
E114
Invalid Measurement !
E115
Temperature Sensor
Error !
E116
Adjustment Error !
E117
BM Change Not Allowed!
E119
Staff Blocked
E120
Image sensor Error!
E121
Adjustment Inverse Staff
Not Allowed!
E123
PtID Change Not Allowed Exit the message by pressing ESC key.

9. Operation Messages

Operation message
Start Tracking!
Stop Tracking!
Tracking Hold!
Abort Measurement!
Counter measure / causes
Make another measurement. If further measurement proved to be futile, check staff position and
Inverse Staff setting, check the lighting condition at the staff and stray light, check focusing and
targeting, check if sufficient length of barcode in the field of view.
Cover the objective telescope with a hand and switch ON the instrument. Hardware communication
failed.
Carry out the adjustment with guided steps, make sure instrument is level and staff is truly vertical in
normal position. Collimation is out of correction range.
Exit to default measurement mode by pressing HEIGHT/DISTANCE key, and change the Benchmark
elevation in the INPUT BM menu mode.
Not enough barcode length for measurement.
Contact services.
Check the staff orientation and staff setting.
Counter measure / remark
Tracking mode starts.
Tracking mode stops.
Press measure key for 3 seconds to restart tracking mode. Tracking will hold after 10 unsuccessful meas-
urements.
Current measuring process is terminated.
Operation Messages
EN
DE
FR
ES
IT
TK
RU
*
|
18
D2

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis