Palazzetti TERMOEASY 14 Produkthandbuch Seite 5

Werbung

UI /
PC
UI /
USER INTERFACE or
PC
PC CONNECTION
3
16
YELLOW
GREEN
WHITE
4
3
2
1
A
ITALIANO
1
SENSORE DI HALL
2
TERMOSTATO ESTERNO
SONDA ACCUMULO /
3
SONDA AMBIENTE
4
SONDA ACQUA DI MANDATA DELIVERy PROBE
SONDA ACQUA DI RITORNO COLD WATER RETURN
5
6
SONDA FUMI
DIFFERENZIALE DI
7
PRESSIONE
RESISTENZA AD
8
INCANDESCENZA
VENTILATORE SCARICO
9
FUMI
10
DOSATORE CARICAMENTO FEEDING SySTEM
TERMOSTATO DI
11
SICUREZZA
PRESSOSTATO Normalmente
Pa
12
Aperto
-
NO
13
SENSORE PORTE
14
CIRCOLATORE
PRESSOSTATO Normalmente
Pa
15
+
Aperto
-
NC
16
Leveltronic (opzionale)
UI /
PANNELLO COMANDI
PC
LIBRETTO 004772790 PALAZZETTI - 10/2013 - Palazzetti - PN - Italy
SCHEMA ELETTRICO - WIRING DIAGRAM - SCHÉMA DE CÂBLAGE
ELEKTRISCHER SCHALTPLAN - DIAGRAMA DE CABLEADO
16
1
A
8
7
6
5
4
3
2
1
P1
P2
P3
+16V
I04
GND
F01
LD2
CN5
LD1
CN12
CN3
F1
L ~230 N
1
comb
8
9
2
NOTE:
PE
L
N
Phase protection, added by customer. Do not change polarity!
230 Vac
* Solo per i modelli con microinterruttore di sicurezza sul coperchio del serbatoio
LEGENDA - LEGEND - LÉGENDE - LEGENDE - LEyENDA
150 mm
ENGLISH
EXHAUST FAN SPEED
SENSOR
THERMOSTAT
ROOM PROBE / WATER
STORAGE PROBE
PROBE
FLUE PROBE
PRESSURE
DIFFERENTIAL
IGNITER
EXHAUST FAN
THERMOSTAT
VACUUM SWITCH
Normally Open
DOOR SENSOR
PUMP
VACUUM SWITCH
Normally Open
Leveltronic (optional)
DISPLAy
2
3
4
A
8
7
6
5
4
3
2
1
8
7
6
5
4
3
2
1
A
P7
P8
P5 P6
T05
T01
GND
F03
F02
+5V
I03 GND
CN7
CN6
air
CN1
O01
O02
O03
O04
10
13
13*
FRANCAIS
CAPTEUR DE HALL
THERMOSTAT
SONDE AMBIANT /
SONDE BALON TAMPON RAUMSONDE / PUFFERSONDE
SONDE DEPART
SONDE RETOUR
SONDE DES FUMEES
DIFFERENTIAL DE
PRESSION
RESISTANCE
EXTRACTEUR DES
FUMEES
SySTEME
D'ALIMENTATION
THERMOSTAT
PRESSOSTAT
Normally Open
SONDE PORTE
CIRCULATEUR
PRESSOSTAT
Normally Open
Leveltronic (optionnel)
TABLEAU DE
COMMANDE
2
K
5
6
T02
T03
T04
Pa-
Pa+
CN11
CN2
CN9
CN10
I01
I02
O05
O06
Pa
+
15
-
NC
14
Pa
12
-
NO
11
11
cod.00 4723 699
DEUTSCH
HALL FUEHLER
RAUMTEMPERATURREGLER
FOERDERLEISTUNGSFUEHLER SONDA MANDADA
RUECKLAUFSONDE
RAUCHSONDE
DRUCKDIFFERENZIAL-SENSOR DIFERENCIAL DE PRESION
GLUTWIDERSTAND
ABGASVENTILATOR
SPENDER
RAUMTEMPERATURREGLER
DRUCKWAECHTER
Normally Open
TUERSONDE
UMWAELZPUMPE
DRUCKWAECHTER
Normally Open
Leveltronic (wahlfrei)
STEUERPANEEL
7
Pa
O07
ESPAÑOL
SONDA REGULAD. VELOC.
TURBINA HUMOS
TERMOSTATO
SONDA AMBIENTE /
SONDA PUFFER
SONDA DE RETORNO
SONDA HUMOS
RESISTENCIA
TURBINA EXPULSION
HUMOS
DOSADOR
TERMOSTATO
PRESOSTATO
Normally Open
SENSOR PUERTA
BOMBA DE CIRCULACION
PRESOSTATO
Normally Open
Leveltronic (opcional)
PANEL DE MANDO
5

Werbung

loading

Diese Anleitung auch für:

Termoeasy 24Termoeasy 18Termoeasy 24/acs