4. Advanced settings and read-out
Press both UP (
Press UP(
Monitoring of energy consumption
The thermostat calculates average time it has been switched on allowing you to monitor your energy consumption.
In the thermostat you can read out:. Total switch-on time in percentage in the latest 2 days, 30 days or 365 days.
Calculation of operational costs per day: (switch-on time:100) x kW x kWh-price x 24 h per day
Example: Read-out: 30 % in the latest 365 days
2 days
30 days
365 days
Software version
Actual sensor temperature
4-event sequence
The present event sequence flashes: Days 1-5, followed by days 6-7. To change, press the UP (
and then day 7 flashing, or all 7 days are flashing. Select the required sequence with the OK (
Max and min allowed temperature range
The temperature setting range of +5˚ to 40˚ C can be limited to prevent at comfort or manual mode a too high or too low temperature
being selected. For example, a wood floor covering should not be allowed to exceed a maximum of 27˚C. Low limitation is used where
the temperature of the floor is required never to fall below the minimum set temperature.
Time and temperature scale selection
Adaptive function
This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set
time. With a start time of 07:00 therefore, the thermostat may switch ON as early as 06:00 so that the desired temperature of 25˚C is
achieved by 07:00. Without this function set, the thermostat will start to heat at the time you set.
) and DOWN (
) buttons together for 3 seconds. INFO is displayed.
) button until you reach the desired sub menu. Select the sub menu with the OK (
Size of heating system: 1,2 kW (ask the installer)
Cost of power: 0,2 EUR / kWh
Calculation: (30:100) x 1,2 kW x 0,2 EUR / kWh x 24 h = 1,7 EUR per day
}
}
}
Press UP (
readouts.
No changes can be made here. Use the OK (
}
5-2: 4 events in 5 days +
2 events in 2 days.
6-1: 4 events in 6 days +
2 events in 1 day
7-0: 4 events in 7 days
Maximum allowed temperature setting. Use the UP (
DOWN (
) button to increase or reduce, and OK (
accept.
Next is displayed LoLi. Press OK (
Minimum allowed temperature setting. Use the UP (
DOWN (
) button to increase or reduce and OK (
accept.
You can select either ˚C or ˚F scale, and 12 or 24 hour clock as
follows:
Press UP (
the required scale with the OK button (
Press the DOWN (
Press OK (
Press OK (
scheduled programme.
) button.
) or DOWN (
) button to show the different
) button until you have days 1-6
) button.
) button to continue.
) or DOWN (
) button to change settings. Confirm
) button.
) button to switch between on and off.
) button to confirm.
) button to end programming and to return to
) button to end.
) or
) button to
) or
) button to