OPERATING INSTRUCTIONS

Measuring AC voltage

The maximum input voltage in the AC-V range is 600 V RMS.
To prevent dangers through electric shocks and/or damage to
the appliance, do not take measurements of voltages of more
than 600 V RMS.
Set the function switch to range "V"
To select the "AC", press the button "SEL".
Insert the black and red test leads into the inputs COM and
INPUT.
Apply the test leads to the circuit to be measured and read the
value.

Measuring resistance / continuity / diode

Before carrying out each resistance measurement, make sure
that the circuit to be measured is not energized and that all
condensers are deenergized.
Set the function switch to range "Ω/
Press the "SEL" button to switch between measuring the
resistance, continuity and diode.
Insert the black and red test leads into the inputs COM and
INPUT.
Apply the test leads to the circuit to be measured and read the
value.
Note: The continuity test is suitable to determine if there are
short circuits / open circuits.