Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Tips & Notes - Conrad 41 59 08 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 41 59 08:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Handling
Use only in dry indoor locations. The product must not get damp or wet! There is a
risk of a life-threatening electric shock!
Never use the product immediately after it has been taken from a cold room to
a warm one. The condensation that forms might destroy your unit. The wall plug
transformer also poses a risk for a potentially fatal electric shock!
Allow the product to reach room temperature, before connecting it to the power sup-
ply and putting it in to use. This may take several hours.
• Avoid the following adverse conditions at the installation location and during trans-
portation:
- Excessive humidity or damp
- Extreme cold (<5°C) or heat (>35°C), direct sunlight,
- Dust or fl ammable gases, fumes or solvents
- Strong vibrations, impacts or blows,
- Strong magnetic fi elds such as those found in the vicinity of machinery or loud-
speakers
• Any maintenance or repair work may only be performed by an authorised repair
shop.
• When setting up the product, make sure that the cables are neither kinked nor
pinched.
• Do not move the product with a hard disk installed, when the latter is in use. Move-
ment during operation may cause the write/read heads in the hard disk to make
contact with the magnetic disk. This may not only lead to data loss but also to
damage of the hard disk! The same applies to the 30-second period after the hard
disk enclosure has been switched off, until the magnetic disk in the hard disk has
come to a standstill.
• If you use the feet included in the delivery, please ensure that the hard disk en-
closure is placed on a stable, level and suffi ciently large surface to prevent it from
topping over or falling down.
Cleaning
Before cleaning the device, disconnect it from the power supply. Use a clean, dry, soft cloth
for cleaning.
Do not use aggressive cleaning agents as these can cause discolouration.
Do not press too strongly on the surface, to prevent scratch marks.
Dust can easily be removed using a clean, long-haired brush and a vacuum cleaner.
Tips & Notes
a) USB 3.0
• USB3.0 devices are backwards compatible. This means that the hard disk enclosure, with
the SATA hard disk installed, also works with conventional USB2.0 or slower USB1.1 ports,
though only at the maximum USB2.0 or USB1.1. speed.
• Depending on the hard disk in your computer, and the hard disk installed in the enclosure, as
well as the motherboard used, USB3.0 supports speeds that may exceed 100MByte/s!
• For USB3.0, the cable should be selected to be as short as possible to avoid a reduction in
the transfer speed.
• To connect the hard disk enclosure to a USB3.0 port on your computer, you must use a
USB3.0 cable (e.g. the one enclosed).
If you use a conventional USB2.0/1.1 cable, only the max. speed supported by USB2.0/1.1
can be achieved and not the transmission speed supported by the USB3.0 cable.
• If you want to connect the hard disk enclosure via a USB hub, the latter must also support the
USB3.0 transfer mode in order to achieve the maximum speed.
b) General
• The LED at the front lights up when the hard disk enclosure is switched on (Power LED func-
tion), or it fl ashes during read/write access.
• USB devices can be connected and disconnected during operation.
You should, however, note that fi les could be damaged or the operating system could crash if
the connection cable is disconnected while data is being transferred or fi les are being opened
by a program.
In Windows, an arrow symbol is displayed in the menu bar when the hard disk (or other USB
devices) is in use. Click this arrow symbol to "separate" the device, i.e. to terminate data
transmission, so you can disconnect the connection cable without risking the loss of data.
Disposal
Dispose of the unserviceable product according to the relevant statutory regulations!

Technical Data

a) Hard disk enclosure
Connection: ..........................................USB3.0
Suitable hard disk for installation: .........SATA, 8.89 cm/3.5"
Dimensions (L x W x H): .......................209 x 42 x 142 mm (without stand)
Weight: .................................................510 g (without stand)
b) Wall plug transformer
Operating voltage: ................................100 - 240 V AC, 50-60 Hz
Output: ..................................................12 V/DC, 2 A
These operating instructions are a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1,
D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfi lming,
or the capture in electronic data processing systems require the prior written approval by the editor.
Reprinting, also in part, is prohibited.
These operating instructions represent the technical status at the time of printing. Changes in
technology and equipment reserved.
© Copyright 2011 by Conrad Electronic SE.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis