Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Technical Data - Renkforce 16 I Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

• Put the cleaned dust filter on top of the activated carbon filter and click it back into
the outer frame.
• Fully reinsert the dry dust filter frame into the dehumidifier; it cannot be inserted
correctly if it is not positioned properly.

Troubleshooting

Problem
Possible cause
The machine does not
Is the power cable
start
plugged in?
The machine is not
Is the water tank full or
working; a red LED
not inserted properly?
is on.
The machine is not
Is the room temperature
working.
over 35 °C or under
5 °C?
Is the humidity in the
room already very low?
The room is not being
Is the room too big
dehumidified properly.
for the rating of the
machine?
Are the ventilation
grilles blocked? Are the
air inlets or dust filter
blocked/dirty?
The dehumidifier is loud
Not stable enough, is it
during operation.
unstable or slanting?
Disposal
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the
relevant statutory regulations.
You thus fulfil your statutory obligations and contribute to the protection of
the environment.

Technical Data

Operating voltage................................220 - 240 V/AC, 50Hz
Power consumption............................max. 280 W
Protection rating .................................IP21
Cable length .........................................150 cm
Room size .............................................max. 32 m
Noise level............................................47 dB(A)
Water tank volume ..............................2.8 l
Coolant/quantity ..................................R134a / 135 g
Air flow rate .........................................max. 210 m
Dehumidifying output ......................... About 16 l/24 hours (at a room temperature of
Operating conditions ..........................+5 to +35 °C, 40 - 90 % RH
Storage conditions..............................+5 to +40 °C, 30 - 90 % RH
Dimensions (W x H x D)......................310 x 543 x 230 mm
Weight ...................................................11.5 kg
Suggested solution
Empty container and insert
fully. The float switch (6)
on the container must be
closed.
The safety thermostat
disables operation at
temperatures above or
below these limits. Wait until
the temperature changes to
a level at which operation is
permitted.
Remove the blocking objects,
clean the dust filter.
Place the dehumidifier on a
horizontal, stable and even
surface.
2
/h
3
30 °C / 80% relative humidity)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.
V3_0416_02_JH

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis