Herunterladen Inhalt Inhalt Diese Seite drucken

Declaration Of Performance (Dop) - TermaTech TT60 Serie Montage- Und Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für TT60 Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
TT60-CPR-2017-Version1
Product type/application:
Type:
Fuel:
Productions no.
AVCP system:
European standard:
Certification:
Essential characteristics
Reaction to fire
Distance to combustible materials Rear: min. 75mm
Declaration of Performance
Emission of combustion products
Product:
Risk of burning fuel falling out
Surface temperature
Clean ability
Mechanical strength
Emission of hazardous materials
Flue gas temperature
Output
Manufacturer:
Energy efficiency
The undersigned is responsible for the manufacturing and conformity with the declared performance.
Certification and requirements:
19.10.2017
Declared performance:
42
Room heater burning solid fuel without hot water supply
TT60: S01-670
TT60S: S01-672
TT60W: S01-674
Wood
Please see nameplate on the back of the oven
TermaTech A/S
Gunnar Clausens Vej 36
8260 Viby J
Denmark
System 3
DS/DIN/EN 13240:2001 + A2:2004/2007
Technologic Institute,
the
product type and declared performance on the basis of type testing and
issued test report no. 300-ELAB-2263-EN.
AI
Sides: min. 350mm
Other safety distances – please see User
and mounting manual
CO = 0,071%
NOx = 84 mg/m³
OGC = 62 mgC/Nmᶟ
PM = 8 mg/m³
Passed
Passed
Passed
Passed
Passed
226° Celsius
6,0 KW
83 %
Søren Toft______________________________
E-mail:
info@termatech.com
Web:
www.termatech.com
Tel.:
+45 8742 0035
notified body no. 1235, has performed determination of
Performance
Harmonised technical
specification
DS/DIN/EN 13240:2001
+ A2:2004/2007

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tt60s serieTt60w serie