Herunterladen Inhalt Inhalt Diese Seite drucken

View X-Over; Window Compressor - IMG STAGE LINE MEGA-215DSP Bedienungsanleitung

Aktiver pa-subwoofer mit dsp
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

 List field TYPE to select the filter type
 Input/Indication field FREQ for the filter
frequency (enter values in Hz)
 Input/Indication field Q/BW for the qual-
ity factor/bandwidth (click Q or BW to
change between quality factor and band-
width)
 Input/Indication field GAIN for filter
boost/attenuation
 High pass filter HPF: input/indication
field for the cut-off frequency (enter val-
ues in Hz, "Off" < 20 Hz)
 High pass filter HPF: list field to select
the filter type
 Low pass filter LPF: input/indication field
for the cut-off frequency (enter values in
Hz, "Off" > 20 kHz)
 Low pass filter LPF: list field to select the
filter type
 Switch MUTE to mute the correspond-
ing output (same effect as )
 Switch INVERT for phase inversion
 Button COMPRESSOR to call up the
configuration window for the compres-
sor of the corresponding output
(
chapter 8.6)
 Rotary knob DELAY with input/indica-
tion field for adjusting the signal delay of
the corresponding output; select the
measuring unit from the list field: time or
distance (for automatic calculation of the
sound delay time)
 Level LIMITER: rotary knob THR with
input/indication field for the threshold
value
 Level LIMITER: rotary knob REL with
input/indication field for the release time









View X-OVER

8.5 View X-OVER (fig. 10)
 Buttons to go to a different view
 Curve diagram of the magnitude fre-
quency response for all high pass filters
and all low pass filters
When a crossover network is created, all
three outputs are represented in a dia-
gram so that the frequency crossovers
are easy to identify. (When the outputs 2
and 3 are linked, only two filter curves
are shown.)
The cut-off frequencies of the filters
are represented by triangular markings
above the curve. To change the fre-
quency, move the corresponding mark-
ing with the mouse (as an alternative to
the numeric input in /).
 High pass filter HPF: input/indication
field for the cut-off frequency (enter val-
ues in Hz; "Off" < 20 Hz)
(same effect as )
 High pass filter HPF: list field to select
the filter type (same effect as )
 Low pass filter LPF: input/indication field
for the cut-off frequency (enter values
in Hz, "Off" > 20 kHz) [same effect as ]
 Low pass filter LPF: list field to select the
filter type (same effect as )
 Input/Indication field G (gain) for adjust-
ing the volume of the output (same effect
as  and )
 Input/indication field D (delay) for ad-
justing the signal delay of the output
(same effect as )
 Level indicators for the outputs
 Switch LINK to link the outputs 2 and 3
(same effect as )
 Switches MUTE to mute the correspond-
ing output (same effect as )
 Switches PHASE INVERT for phase
inversion of the corresponding output
(same effect as )

8.6 Window COMPRESSOR

Compressor configuration window
 Button BACK to return to the previous
view
 Level indicator VU and gain reduction GR
 Rotary knob "Threshold" with input/indi-
cation field for the threshold value
 Rotary knob "Attack" with input/indica-
tion field for the attack time
 Rotary knob "Hold" with input/indication
field for the hold time
 Rotary knob "Release" with input/indica-
tion field for the release time
 Rotary knob "Ratio" with input/indication
field for the compression ratio
 Rotary knob "Makeup Gain" with input/
indication field for level loss compensa-
tion












21