Herunterladen Inhalt Inhalt Diese Seite drucken

Important Safety Instructions - ECOFLEX 07 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Limiting range between two indexes (ECOFLEX EL, SL)
Proceed as in above mentioned section for maximum setting. Switch off the unit. Release
convector from mounting bracket.Release second latch from thermostat control knob. Turn
and place the knob on the desired minimum index. Correctly screw latch in the hole
located left from index"F". The knob should turn freely between two limit temperatures.
Locking rotation on index (ECOFLEX EL, SL)
Switch off the unit. Release unit from mounting bracket. Release one latch. Turn and place
knob precisely on the desired index.Correctly screw the latch in the hole indicated by
index"F". The knob should be blocked.
Calibration (ECOFLEX EL, SL)
To achieve trouble-free temperature control,the appliance must be set as described below.
With the doors and windows closed, arrange thermometer in the centre of the room 1,2m
above the floor. Set the on/off switch to position"M". Set the thermostat control knob to
the maximum position. As soon as the required room temperature is reached, for example
the thermometer indicates 20°C, slowly turn back the thermostat control knob until the
indicator light goes off. After the temperature has been set the thermostat will automatically
keeps the room temperature constant by successively switching on and off the power
supply to the unit.
Switch off (ECOFLEX EL, SL)
To switch off the convector without acting on the thermostat setting set the on/ off switch
to position"A".
Removing unit
Before removing the unit from its mounting bracket set the on/ off switch to position"A". If
an external pilot wire is used cut off its power supply too. Use screwdriver to release
locking parts. Disconnect the power supply cable from the wall junction box. Lift the unit
vertically to clear it from the bracket.
Notice
Only qualified, approved personnel are authorized to work on convector. The installation
must be disconnected from the power supply before starting any work. If the installation is
programmed by pilot wire,be sure to cut off the power supply to the concerned unit(s) and
pilot wire before starting work.
Economical operation (ECOFLEX EL, SL)
Switch off the power supply to your heating units,on/off switch to position"A"when you
ventilating your rooms for any lengthy period of time. Whenever you do not use a room
(guest room) or if you do not use your home for any extended period of time (vacation)
set the thermostat knob to the position *. The room temperature will then be automatically
kept on value approximately 7°C.

Important safety instructions

Do not cover your heating unit in any way. The"DO NOT COVER"warning tag is there to
remind you that any material covering the unit can catch fire. Never place or hang any
furniture or curtains in front of convector,see picture No.9. It must be ensured free air
GB
circulation. Regularly,minimum each time before the starting of heating season clean the
inlet and outlet grid from dust.